⚡ 4mm² Grün/Gelb
EBROM H07V-U single-core wire rigid 4mm² green/yellow 1,31 €
H07V-U rigid installation wire High-quality rigid installation wire, ideal for fixed installation. Technical information Fire class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Cl.1 = single-wire Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Cold-resistant according to EN 60811-504+505+506: Yes Single-wire VDE 0281 Usage: for protected installation in equipment as well as in and on luminaires. Approved for installation in conduits on and under plaster, but only for signal systems. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U= 300/500 V, maximum permissible operating voltage, three-phase and AC current Uo/U= 330/550 V, DC current Uo/U = 495/825 V, test AC voltage = 2000 V Installation note: When wiring luminaires where the connection area of the wires is not protected from UV radiation and heat (caused by the illuminants), a protective sleeve must always be pushed over the exposed wires. Otherwise, decomposition of the insulation will occur depending on the duty cycle. Technical data Cable type H07V-U Cross-section 4mm² Colour Green/Yellow Nominal voltage 300/500V Standard VDE 0281
⚡ 6mm² Schwarz
Bestseller
EBROM H07V-K flexible single-core wire 6mm² black 2,40 €
H07V-K flexible wiring cable High-quality flexible multi-strand wiring cable. Technical information Reaction to fire class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Class 5 = fine-stranded Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Fine-stranded VDE 0281 Usage: In dry rooms, in equipment, switchgear and distribution cabinets, in conduits on or under plaster as well as for protected installation in luminaires. Not permitted for: direct installation in plaster! Installation on cable trays, in troughs (except covered plastic troughs) and the like. Approved for the internal wiring of devices for a mains voltage up to 1000 V AC and up to 750 V DC against earth. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U = 450/750 V Maximum permissible operating voltage: Three-phase and AC voltage Uo/U = 495/825 V; DC voltage Uo/U = 743/1238 V; Test AC voltage = 2500 V Installation note: When wiring in luminaires where the connection area of the cores is not protected from UV radiation and heat (generated by the light sources), a protective tube must always be slid over the exposed cores. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H07V-K Cross-section 6mm² Colour Black
⚡ 6mm² Schwarz
EBROM H07V-U single-core wire rigid 6mm² black 1,72 €
H07V-U rigid wiring cable High-quality rigid wiring cable, ideal for fixed installation. Technical information Fire behavior class according to EN 13501-6: Eca Flame-retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Cl.1 = single-wire Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Cold-resistant according to EN 60811-504+505+506: Yes Single-wire VDE 0281 Application: for protected installation in devices as well as in and on luminaires. Approved for installation in conduits on and under plaster, however, only for signal systems. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U= 300/500 V, Maximum permissible operating voltage, three-phase and alternating current Uo/U= 330/550 V, direct current Uo/U = 495/825 V, test alternating voltage = 2000 V Installation instruction: When wiring in luminaires where the connection area of the cores is not protected against UV radiation and heat (caused by the illuminants), a protective sleeve must generally be pushed over the exposed cores. Otherwise, decomposition of the insulation occurs depending on the duty cycle. Technical data Cable type H07V-U Cross-section 6mm² Color Black Nominal voltage 300/500V Standard VDE 0281
⚡ 6mm² Rot
EBROM H07V-K flexible core wire 6mm² red 2,40 €
Battery cable for many areas of application - 99.9% OFC copper - sold by the meter according to customer requirements - various cross-sections - With a fine-stranded copper wire, the nominal cross-section cannot be reliably determined from the diameter of the wire bundle, not even with a caliper. Please use the cable imprint or the data sheet. The circular area calculation using the circle formula A = π × d² / 4 applies to a solid, circular conductor. The sheath and insulation are not part of the conductor area. We are happy to help if you have any questions regarding identification. Technical data Cable type H07V-K Cross-section 6mm² Color Red
⚡ 6mm² Blau
EBROM H07V-K flexible wire 6mm² blue 2,40 €
Battery cable core wire BLUE H07V-K 4-6 - 10-16 - 25 – 35 – 50 – 70-95 mm² - Battery cable 99.9% copper - Sold by the meter 4mm² 6mm² 10mm² 16mm² 25mm² 35mm² 50mm² 70mm² - Caravan, truck, boat Technical data Cable type H07V-K Cross-section 6mm² Color Blue
⚡ 6mm² Braun
EBROM H07V-K flexible single-core wire 6mm² brown 2,40 €
H07V-K flexible wiring cable High-quality flexible stranded wiring cable. Technical information Reaction to fire class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Class 5 = fine-stranded Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Fine-stranded VDE 0281 Application: In dry rooms, in equipment, switchgear and distribution systems, in conduits on or under plaster as well as for protected installation in luminaires. Not permitted for: direct installation in plaster! Installation on cable trays, in troughs (except for covered plastic troughs) and the like. For the internal wiring of devices approved for a mains voltage up to 1000 V AC and up to 750 V DC against earth. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U = 450/750 V Maximum permissible operating voltage: Three-phase and AC current Uo/U = 495/825 V; DC current Uo/U = 743/1238 V; Test AC voltage = 2500 V Installation note: For wiring in luminaires where the connection area of the cores is not protected from UV radiation and heat (caused by the light sources), a protective sleeve must always be pushed over the exposed cores. Otherwise, decomposition of the insulation will occur depending on the operating time. Technical data Cable type H07V-K Cross-section 6mm² Colour Brown
⚡ 6mm² Grau
EBROM H07V-K Flexible Single Core Cable 6mm² Grey 2,40 €
H07V-K flexible wiring cable High-quality flexible multi-stranded wiring cable. Technical information Reaction to fire class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Class 5 = fine-stranded Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Fine-stranded VDE 0281 Application: In dry rooms, in equipment, switchgear and distribution boards, in conduits on or under plaster, as well as for protected installation in luminaires. Not permitted for: direct installation in plaster! Installation on trays, in troughs (except for covered plastic troughs) and the like. Approved for internal wiring of equipment for a mains voltage of up to 1000 V AC and up to 750 V DC against earth. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U = 450/750 V Maximum permissible operating voltage: Three-phase and AC current Uo/U = 495/825 V; DC current Uo/U = 743/1238 V; Test AC voltage = 2500 V Installation note: When wiring luminaires where the connection area of the wires is not protected from UV radiation and heat (generated by the lamps), a protective sleeve must always be pushed over the exposed wires. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H07V-K Cross-section 6mm² Color Gray
⚡ 6mm² Hellblau
EBROM H07V-K flexible single core wire 6mm² light blue 2,40 €
H07V-K flexible wiring cable High-quality flexible multi-strand wiring cable. Technical information Reaction to fire class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Class 5 = fine-stranded Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Fine-stranded VDE 0281 Application: In dry rooms, in equipment, switchgear and distribution cabinets, in conduits on or under plaster as well as for protected installation in light fittings. Not permitted for: direct installation in plaster! Installation on cable trays, in troughs (except for covered plastic troughs) and the like. Approved for internal wiring of equipment for a mains voltage up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U = 450/750 V Maximum permissible operating voltage: Three-phase and AC current Uo/U = 495/825 V; DC current Uo/U = 743/1238 V; Test AC voltage = 2500 V Installation note: When wiring in light fittings where the connection area of the wires is not protected from UV radiation and heat (generated by the light source), a protective sleeve must always be pushed over the exposed wires. Otherwise, decomposition of the insulation will occur depending on the operating time. Technical data Cable type H07V-K Cross-section 6mm² Color Light blue
⚡ 6mm² Hellblau
EBROM H07V-U single-core wire rigid 6mm² light blue 1,72 €
H07V-U rigid installation wire High-quality rigid installation wire, ideal for fixed installation. Technical information Fire reaction class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Cl.1 = solid Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Cold-resistant according to EN 60811-504+505+506: Yes Solid VDE 0281 Application: for protected installation in equipment as well as in and on luminaires. Approved for installation in conduits on and under plaster, but only for signaling systems. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U= 300/500 V, maximum permissible operating voltage, three-phase and alternating current Uo/U= 330/550 V, direct current Uo/U = 495/825 V, test alternating voltage = 2000 V Installation note: When wiring luminaires where the connection area of the wires is not protected from UV radiation and heat (caused by the light sources), a protective sleeve must always be pushed over the exposed wires. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H07V-U Cross-section 6mm² Color Light blue Nominal voltage 300/500V Standard VDE 0281
⚡ 6mm² Dunkelblau
EBROM H07V-K flexible single core wire 6mm² dark blue 2,40 €
H07V-K flexible wiring cable High-quality flexible multi-stranded wiring cable. Technical information Reaction to fire class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Class 5 = finely stranded Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Finely stranded VDE 0281 Application: In dry rooms, in equipment, switchgear and distribution systems, in conduits on or under plaster, as well as for protected installation in luminaires. Not permitted for: direct installation in plaster! Installation on cable trays, in troughs (except for covered plastic troughs) and the like. Approved for internal wiring of equipment for a mains voltage up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U = 450/750 V Maximum permissible operating voltage: Three-phase and AC current Uo/U = 495/825 V; DC current Uo/U = 743/1238 V; Test AC voltage = 2500 V Installation note: When wiring in luminaires where the connection area of the cores is not protected from UV radiation and heat (caused by the light sources), a protective sleeve must always be pushed over the exposed cores. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H07V-K Cross-section 6mm² Color Dark blue
⚡ 6mm² Grün/Gelb
EBROM H07V-K Flexible Single Core Wire 6mm² Green/Yellow 2,40 €
H07V-K flexible wiring cable High-quality flexible multi-strand wiring cable. Technical information Fire behavior class according to EN 13501-6: Eca Flame-retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Cl.5 = finely stranded Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Finely stranded VDE 0281 Application: In dry rooms, in equipment, switchgear and distribution systems, in conduits on or under plaster as well as for protected installation in luminaires. Not permitted for: direct installation in plaster! Installation on trays, in conduits (except for covered plastic conduits) and the like. Approved for internal wiring of appliances for a mains voltage up to 1000 V AC and up to 750 V DC against earth. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U = 450/750 V Maximum permissible operating voltage: Three-phase and AC current Uo/U = 495/825 V; DC current Uo/U = 743/1238 V; Test AC voltage = 2500 V Installation note: For wiring in luminaires where the connection area of the wires is not protected against UV radiation and heat (caused by the light sources), a protective sleeve must always be pushed over the exposed wires. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H07V-K Cross-section 6mm² Color Green/Yellow
⚡ 6mm² Grün/Gelb
EBROM H07V-U rigid core wire 6mm² green/yellow 1,72 €
H07V-U rigid installation wire High-quality rigid installation wire, ideal for fixed installation. Technical information Fire behavior class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Cl.1 = single-wire Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Cold-resistant according to EN 60811-504+505+506: Yes Single-wire VDE 0281 Application: for protected installation in equipment as well as in and on luminaires. Approved for installation in conduits on and under plaster, but only for signal systems. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U= 300/500 V, maximum permissible operating voltage, three-phase and AC current Uo/U= 330/550 V, DC current Uo/U = 495/825 V, test AC voltage = 2000 V Installation instruction: When wiring in luminaires where the connection area of the cores is not protected from UV radiation and heat (caused by the illuminants), a protective sleeve must always be pushed over the exposed cores. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H07V-U Cross-section 6mm² Color Green/Yellow Nominal voltage 300/500V Standard VDE 0281
⚡ 10mm² Schwarz
EBROM H07V-K flexible single-core wire 10mm² black 2,94 €
Flexible EBROM battery cable type H07V-K. Easy to process and install due to the flexible properties of the many copper strands. 99.9% OFC full copper, highest quality level. Technical data: Max. operating temperature (fixed installation): -30°C to +80°C. Max. operating temperature (moved): -5°C to +70°C. Please check the temperature of the place of use/area of application before use!! Protected installation is recommended! Keep away from hot components and oils! Article class and specifications: Article class: Core cable. Conductor class: Class 5 = fine-stranded. Core insulation: PVC. Nominal voltage: U0 450 V, U 750 V. Conductor material: Copper, bare, 99.99% OFC. With a fine-stranded copper strand, the nominal cross-section cannot be reliably determined from the diameter of the wire bundle, not even with a caliper gauge. Please use the cable imprint or the data sheet. The circular area calculation using the circle formula A = π × d² / 4 applies to a solid, circular conductor. Sheathing and insulation are not part of the conductor area. We are happy to help with questions regarding classification. Technical data Cable type H07V-K Cross-section 10mm² Color Black
⚡ 10mm² Rot
EBROM H07V-K flexible single-core wire 10mm² Red 2,94 €
Battery cables for many areas of application - 99.9% OFC copper - sold by the meter according to customer requirements - various cross-sections - For fine-stranded copper wire, the nominal cross-section cannot be reliably determined from the diameter of the wire bundle, not even with a caliper. Use the cable imprint or the data sheet. The circular area calculation using the circle formula A = π × d² / 4 applies to a solid, circular conductor. The sheath and insulation are not part of the conductor area. If you have any questions about classification, we are happy to help. Technical data Cable type H07V-K Cross-section 10mm² Color Red
⚡ 10mm² Blau
EBROM H07V-K Flexible Single Core Wire 10mm² Blue 2,94 €
Flexible EBROM battery cable of type H07V-K. Easy to process and install due to the flexible properties of the many copper strands. 99.9% OFC full copper, highest quality level. Technical data: Max. operating temperature (fixed installation): -30°C to +80°C. Max. operating temperature (moved): -5°C to +70°C. Please check the temperature of the place of use/area of application before use!! Protected installation is recommended! Keep away from hot components and oils! Article class and specifications: Article class: Core cable. Conductor class: Class 5 = fine-stranded. Core insulation: PVC. Nominal voltage: U0 450 V, U 750 V. Conductor material: Copper, bare, 99.99% OFC. With a fine-stranded copper wire, the nominal cross-section cannot be reliably determined from the diameter of the wire bundle, not even with a caliper. Use the cable imprint or the data sheet. The circular area calculation using the circle formula A = π × d² / 4 applies to a solid, circular conductor. The sheath and insulation are not part of the conductor area. We are happy to help if you have any questions regarding allocation. Technical data Cable type H07V-K Cross-section 10mm² Color Blue

Free standard shipping to Germany from €60

Fast shipping within Germany

In-house German assembly

Cable assemblies from our own production

Specialist Consulting

Consultation by phone at +49 8074 9176911
PayPal Visa Mastercard SEPA Klarna