⚡ 0.5mm² Schwarz
EBROM H05V-K flexible single-core cable 0.5mm² black 0,34 €
Single-core stranded wire, fine-stranded conductors of conductor class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear and distribution boards, in conduits on and under plaster, as well as in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power systems for measuring, control and regulation purposes. Not permitted for direct installation under plaster. For the internal wiring of devices approved for a mains voltage up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC current Uo/U = 330/550 V; DC current Uo/U = 495/825 V; AC test voltage = 2000 V - Installation note: When wiring in luminaires where the connection area of the wires is not protected against UV radiation and heat (caused by the light sources), a protective sleeve must always be pushed over the exposed wires. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H05V-K Cross-section 0.5mm² Colour Black Nominal voltage 300/500V Standard VDE 0281
⚡ 0.5mm² Rot
EBROM H05V-K flexible single-core wire 0.5mm² red 0,34 €
Single-core stranded wire, fine-stranded conductor class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear and distribution boards, in conduits on and under plaster, as well as in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power systems for the purpose of measuring, controlling and regulating. Not permitted for direct installation under plaster. Approved for internal wiring of equipment for mains voltages up to 1000 V AC and 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and alternating current Uo/U = 330/550 V; direct current Uo/U = 495/825 V; test AC voltage = 2000 V - Installation note: When wiring luminaires where the connection area of the cores is not protected from UV radiation and heat (generated by the lamps), a protective sleeve must always be pushed over the exposed cores. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H05V-K Cross-section 0.5mm² Color Red Nominal voltage 300/500V Standard VDE 0281
⚡ 0.5mm² Braun
EBROM H05V-K flexible single-core wire 0.5mm² brown 0,34 €
Single-core stranded wire, fine-stranded conductors of conductor class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear and distributors, in conduits on and under plaster, as well as in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power installations for the purpose of measuring, controlling, and regulating. Not permitted for direct installation under plaster. Approved for the internal wiring of equipment for a mains voltage of up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC current Uo/U = 330/550 V; DC current Uo/U = 495/825 V; Test AC voltage = 2000 V - Installation note: For wiring in luminaires where the connection area of the wires is not protected from UV radiation and heat (generated by the lamps), a protective sleeve must always be pushed over the exposed wires. Otherwise, decomposition of the insulation will occur depending on the duty cycle. Technical Data Cable type H05V-K Cross-section 0.5mm² Color Brown Nominal voltage 300/500V Standard VDE 0281
⚡ 0.5mm² Grau
EBROM H05V-K flexible single-core cable 0.5mm² grey 0,34 €
Single-core stranded, fine-stranded wires of conductor class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear, and distribution boards, in conduits on and under plaster, as well as in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in high-voltage installations for the purpose of measuring, controlling, and regulating. Not permitted for direct installation under plaster. Approved for internal wiring of equipment for mains voltages up to 1000 V AC and up to 750 V DC against earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC current Uo/U = 330/550 V; DC current Uo/U = 495/825 V; Test AC voltage = 2000 V - Installation note: When wiring in luminaires where the connection area of the wires is not protected from UV radiation and heat (caused by the light sources), a protective sleeve must always be slid over the exposed wires. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H05V-K Cross-section 0.5mm² Colour Grey Nominal voltage 300/500V Standard VDE 0281
⚡ 0.5mm² Weiss
EBROM H05V-K flexible single-core wire 0.5mm² white 0,34 €
Single core, multi-stranded, fine-stranded conductors of conductor class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear and control cabinets, in conduits on and under plaster as well as in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power installations for the purpose of measuring, controlling and regulating. Not permitted for direct installation under plaster. Approved for internal wiring of equipment for mains voltages up to 1000 V AC and up to 750 V DC against earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC current Uo/U = 330/550 V; DC current Uo/U = 495/825 V; AC test voltage = 2000 V - Installation note: When wiring in luminaires where the connection area of the wires is not protected from UV radiation and heat (caused by the illuminants), a protective sleeve must always be pushed over the exposed wires. Otherwise, the insulation will decompose depending on the duty cycle. Technical data Cable type H05V-K Cross-section 0.5mm² Colour White Nominal voltage 300/500V Standard VDE 0281
⚡ 0.5mm² Gelb
EBROM H05V-K flexible single-core wire 0.5mm² yellow 0,34 €
Single-core stranded wire, fine-stranded conductors of conductor class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear, and distribution boards, in conduits on and under plaster, as well as in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power installations for measuring, control, and regulation purposes. Not permitted for direct installation under plaster. For internal wiring of devices, approved for mains voltages up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC voltage Uo/U = 330/550 V; DC voltage Uo/U = 495/825 V; AC test voltage = 2000 V - Installation instruction: When wiring in luminaires where the connection area of the cores is not protected from UV radiation and heat (generated by the light sources), a protective sleeve must always be slid over the exposed cores. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H05V-K Cross-section 0.5mm² Colour Yellow Nominal voltage 300/500V Standard VDE 0281
⚡ 0.5mm² Grün
EBROM H05V-K single core wire flexible 0.5mm² green 0,34 €
Single-core stranded, fine-stranded conductors of conductor class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear, and control cabinets, in conduits on or under plaster, as well as in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power installations for the purpose of measuring, controlling, and regulating. Not permitted for direct installation under plaster. Approved for internal wiring of equipment with a mains voltage of up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and alternating current Uo/U = 330/550 V; direct current Uo/U = 495/825 V; test AC voltage = 2000 V - Installation note: When wiring in luminaires where the connection area of the cores is not protected from UV radiation and heat (generated by the lamps), a protective sleeve must always be pushed over the exposed cores. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H05V-K Cross-section 0.5mm² Colour Green Nominal voltage 300/500V Standard VDE 0281
⚡ 0.5mm² Orange
EBROM H05V-K flexible single-core wire 0.5mm² orange 0,34 €
Multi-strand single core, fine-wired cores of core class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear and distribution boards, in conduits on and under plaster, and in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power installations for measuring, control and regulation purposes. Not permitted for direct installation under plaster. Approved for the internal wiring of equipment with a mains voltage of up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC current Uo/U = 330/550 V; direct current Uo/U = 495/825 V; AC test voltage = 2000 V - Installation note: For wiring in luminaires where the connection area of the cores is not protected from UV radiation and heat (caused by the bulbs), a protective sleeve must always be pushed over the exposed cores. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H05V-K Cross-section 0.5mm² Color Orange Nominal voltage 300/500V Standard VDE 0281
⚡ 0.5mm² Violett
EBROM H05V-K flexible single-core wire 0.5mm² violet 0,34 €
Single-core stranded, finely stranded conductors of conductor class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear and distribution boards, in conduits on and under plaster, as well as in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power installations for measuring, control and regulation purposes. Not permitted for direct installation under plaster. For the internal wiring of equipment, approved for a mains voltage of up to 1000 V AC and up to 750 V DC against earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC current Uo/U = 330/550 V; DC current Uo/U = 495/825 V; Test AC voltage = 2000 V - Installation note: When wiring in luminaires where the connection area of the cores is not protected from UV radiation and heat (generated by the lamps), a protective sleeve must always be slid over the exposed cores. Otherwise, the insulation will decompose depending on the duty cycle. Technical data Cable type H05V-K Cross-section 0.5mm² Colour Violet Nominal voltage 300/500V Standard VDE 0281
⚡ 0.5mm² Hellblau
EBROM H05V-K single core flexible wire 0.5mm² light blue 0,34 €
Stranded single core, fine-stranded conductor class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear and distribution boards, in conduits on and under plaster, and in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power installations for the purpose of measuring, controlling and regulating. Not permitted for direct installation under plaster. For the internal wiring of equipment, approved for a mains voltage up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: three-phase and AC current Uo/U = 330/550 V; direct current Uo/U = 495/825 V; test AC voltage = 2000 V - Installation note: When wiring luminaires where the connection area of the cores is not protected from UV radiation and heat (caused by the illuminants), a protective sleeve must always be slid over the exposed cores. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H05V-K Cross-section 0.5mm² Colour Light blue Nominal voltage 300/500V Standard VDE 0281
⚡ 0.5mm² Dunkelblau
EBROM H05V-K flexible single core wire 0.5mm² dark blue 0,34 €
Single-core stranded wire, fine-stranded conductor class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear and distribution boards, in conduits on and under plaster, and in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power installations for the purpose of measuring, controlling and regulating. Not permitted for direct installation under plaster. For internal wiring of equipment, approved for a mains voltage of up to 1000 V AC and up to 750 V DC against earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC current Uo/U = 330/550 V; direct current Uo/U = 495/825 V; AC test voltage = 2000 V - Installation note: When wiring in luminaires where the connection area of the cores is not protected against UV radiation and heat (caused by the illuminants), a protective sleeve must always be pushed over the exposed cores. Otherwise, decomposition of the insulation will occur depending on the duty cycle. Technical data Cable type H05V-K Cross-section 0.5mm² Colour Dark blue Nominal voltage 300/500V Standard VDE 0281
⚡ 0.5mm² Grün/Gelb
EBROM H05V-K flexible single-core wire 0.5mm² Green/Yellow 0,34 €
Stranded single core, class 5 fine-stranded wires according to VDE 0281, for use in dry rooms, in equipment, switchgear, and distribution boards, in conduits on and under plaster, as well as in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power systems for measuring, control, and regulation purposes. Not permitted for direct installation under plaster. Approved for the internal wiring of equipment with a mains voltage up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Rated voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and alternating current Uo/U = 330/550 V; direct current Uo/U = 495/825 V; test AC voltage = 2000 V - Installation note: When wiring in luminaires where the connection area of the wires is not protected from UV radiation and heat (generated by the lamps), a protective sleeve must always be pushed over the exposed wires. Otherwise, the insulation will decompose depending on the duty cycle. Technical data Cable type H05V-K Cross-section 0.5mm² Color Green/Yellow Rated voltage 300/500V Standard VDE 0281
⚡ 0.75mm² Schwarz
EBROM H05V-K flexible single-core wire 0.75mm² black 0,40 €
Single-core stranded wire, fine-stranded conductor class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear and distribution boards, in conduits on and under plaster, as well as in closed installation ducts. For protected installation in and on light fittings. In and on electronic equipment in power installations for the purpose of measuring, controlling and regulating. Not permitted for direct laying under plaster. Approved for the internal wiring of equipment for mains voltages up to 1000 V AC and up to 750 V DC against earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC current Uo/U = 330/550 V; direct current Uo/U = 495/825 V; AC test voltage = 2000 V - Installation note: When wiring in light fittings where the connection area of the wires is not protected from UV radiation and heat (generated by the bulbs), a protective sleeve must always be pushed over the exposed wires. Otherwise, decomposition of the insulation will occur depending on the operating time. Technical data Cable type H05V-K Cross-section 0.75mm² Color Black Nominal voltage 300/500V Standard VDE 0281
⚡ 0.75mm² Rot
EBROM H05V-K flexible single-core wire 0.75mm² red 0,40 €
Single-core stranded wire, fine-stranded conductor class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear and distribution boards, in conduits on and under plaster, as well as in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power installations for the purpose of measuring, controlling, and regulating. Not permitted for direct installation under plaster. For the internal wiring of equipment approved for a mains voltage of up to 1000 V AC and up to 750 V DC against earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC current Uo/U = 330/550 V; direct current Uo/U = 495/825 V; test AC voltage = 2000 V - Installation note: When wiring luminaires where the connection area of the wires is not protected from UV radiation and heat (caused by the light sources), a protective sleeve must always be slid over the exposed wires. Otherwise, decomposition of the insulation will occur depending on the operating time. Technical data Cable type H05V-K Cross-section 0.75mm² Color Red Nominal voltage 300/500V Standard VDE 0281
⚡ 0.75mm² Braun
EBROM H05V-K flexible single-core wire 0.75mm² brown 0,40 €
Single-core stranded wire, fine-stranded conductor class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear and distribution boards, in conduits on and under plaster, as well as in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power systems for measuring, control, and regulation purposes. Not permitted for direct installation under plaster. For internal wiring of equipment, approved for a mains voltage up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC current Uo/U = 330/550 V; direct current Uo/U = 495/825 V; AC test voltage = 2000 V - Installation note: When wiring in luminaires where the connection area of the wires is not protected from UV radiation and heat (generated by the lamps), a protective sleeve must always be slid over the exposed wires. Otherwise, decomposition of the insulation will occur, depending on the duration of operation. Technical data Cable type H05V-K Cross-section 0.75mm² Colour Brown Nominal voltage 300/500V Standard VDE 0281

Free standard shipping to Germany from €60

Fast shipping within Germany

In-house German assembly

Cable assemblies from our own production

Specialist Consulting

Consultation by phone at 08074/9176911
Generic Generic Generic Generic Generic