⚡ 1.0mm² Grün
EBROM H05V-K flexible single core wire 1.0mm² green 0,47 €
Single-core stranded wire, fine-stranded conductors of conductor class 5 according to VDE 0281, for use in dry rooms, in devices, switchgear and distribution boards, in conduits on and under plaster, as well as in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power systems for the purpose of measuring, controlling and regulating. Not permitted for direct installation under plaster. For internal wiring of equipment approved for a mains voltage of up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC current Uo/U = 330/550 V; DC current Uo/U = 495/825 V; Test AC voltage = 2000 V - Installation note: When wiring in luminaires where the connection area of the wires is not protected from UV radiation and heat (caused by the illuminants), a protective sleeve must always be pushed over the exposed wires. Otherwise, decomposition of the insulation will occur depending on the operating time. Technical data Cable type H05V-K Cross-section 1.0mm² Colour Green Nominal voltage 300/500V Standard VDE 0281
⚡ 1.0mm² Orange
EBROM H05V-K flexible single-core cable 1.0mm² orange 0,47 €
Single-core stranded wire, fine-stranded conductor class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear, and distribution boards, in conduits on or under plaster, as well as in closed installation ducts. For protected installation in and on lighting fixtures. In and on electronic equipment in power systems for the purpose of measuring, controlling, and regulating. Not permitted for direct installation under plaster. For internal wiring of equipment approved for a mains voltage of up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC voltage Uo/U = 330/550 V; DC voltage Uo/U = 495/825 V; Test AC voltage = 2000 V - Installation note: When wiring in lighting fixtures where the connection area of the wires is not protected from UV radiation and heat (generated by the bulbs), a protective sleeve must always be pushed over the exposed wires. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H05V-K Cross-section 1.0mm² Color Orange Nominal voltage 300/500V Standard VDE 0281
⚡ 1.0mm² Violett
EBROM H05V-K flexible core cable 1.0mm² violet 0,47 €
Single-core stranded, fine-wired conductors of conductor class 5 according to VDE 0281, for use in dry rooms, in devices, switchgear and distribution boards, in conduits on and under plaster, as well as in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power installations for the purpose of measuring, controlling, and regulating. Not permitted for direct installation under plaster. For internal wiring of devices, approved for a mains voltage up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC current Uo/U = 330/550 V; DC current Uo/U = 495/825 V; Test AC voltage = 2000 V - Installation note: When wiring in luminaires where the connection area of the wires is not protected from UV radiation and heat (caused by the illuminants), a protective sleeve must always be slid over the exposed wires. Otherwise, decomposition of the insulation will occur depending on the operating time. Technical data Cable type H05V-K Cross-section 1.0mm² Color Violet Nominal voltage 300/500V Standard VDE 0281
⚡ 1.0mm² Hellblau
EBROM H05V-K flexible single core wire 1.0mm² light blue 0,47 €
Stranded single core, fine-stranded conductors of conductor class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear, and control systems, in conduits on and under plaster, as well as in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment for power installations for measuring, control, and regulation purposes. Not permitted for direct installation under plaster. Approved for internal wiring of devices for a mains voltage up to 1000 V AC and up to 750 V DC against earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC Uo/U = 330/550 V; DC Uo/U = 495/825 V; Test AC voltage = 2000 V - Installation note: When wiring in luminaires where the connection area of the cores is not protected against UV radiation and heat (caused by the light sources), a protective sleeve must always be slid over the exposed cores. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H05V-K Cross-section 1.0mm² Color Light blue Nominal voltage 300/500V Standard VDE 0281
⚡ 1.0mm² Dunkelblau
EBROM H05V-K flexible single-core wire 1.0mm² dark blue 0,47 €
Single-core stranded, fine-wired conductors of conductor class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear, and distributors, in conduits on and under plaster, as well as in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power installations for the purpose of measuring, controlling, and regulating. Not permitted for direct installation under plaster. Approved for the internal wiring of equipment for mains voltages up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Rated voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC current Uo/U = 330/550 V; DC current Uo/U = 495/825 V; Test AC voltage = 2000 V - Installation note: When wiring luminaires where the connection area of the wires is not protected from UV radiation and heat (generated by the bulbs), a protective sleeve must always be slid over the exposed wires. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H05V-K Cross-section 1.0mm² Color Dark blue Rated voltage 300/500V Standard VDE 0281
⚡ 1.0mm² Grün/Gelb
EBROM H05V-K flexible wire 1.0mm² green/yellow 0,47 €
Single-core stranded, finely stranded conductors of conductor class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear and distribution boards, in conduits on and under plaster as well as in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power installations for measuring, control and regulation purposes. Not permitted for direct installation under plaster. Approved for the internal wiring of equipment with a mains voltage of up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC Uo/U = 330/550 V; DC Uo/U = 495/825 V; Test AC voltage = 2000 V - Installation note: When wiring in luminaires where the connection area of the wires is not protected from UV radiation and heat (caused by the illuminants), a protective sleeve must always be pushed over the exposed wires. Otherwise, decomposition of the insulation will occur depending on the operating time. Technical data Cable type H05V-K Cross-section 1.0mm² Colour Green/Yellow Nominal voltage 300/500V Standard VDE 0281
⚡ 1.5mm² Schwarz
Bestseller
EBROM H07V-K flexible single-core wire 1.5mm² black 0,48 €
H07V-K flexible wiring cable High-quality flexible stranded wiring cable. Technical information Reaction to fire class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Class 5 = fine-stranded Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Fine-stranded VDE 0281 Application: In dry rooms, in equipment, switchgear and distribution systems, in conduits on or under plaster as well as for protected installation in light fixtures. Not permitted for: direct installation in plaster! Installation on trays, in channels (except for covered plastic channels) and the like. Approved for internal wiring of equipment for a mains voltage up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U = 450/750 V Maximum permissible operating voltage: Three-phase and AC voltage Uo/U = 495/825 V; DC voltage Uo/U = 743/1238 V; Test AC voltage = 2500 V Installation note: When wiring in light fixtures where the connection area of the cores is not protected from UV radiation and heat (caused by the light sources), a protective sleeve must always be pushed over the exposed cores. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H07V-K Cross-section 1.5mm² Colour Black
⚡ 1.5mm² Schwarz
EBROM H07V-U single-core wire rigid 1.5mm² black 0,48 €
H07V-U rigid wiring cable High-quality rigid wiring cable, ideal for fixed installation. Technical information Fire reaction class according to EN 13501-6: Eca Flame-retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Cl.1 = single-wire Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Cold-resistant according to EN 60811-504+505+506: Yes Single-wire VDE 0281 Usage: for protected installation in equipment as well as in and on luminaires. Approved for installation in conduits on and under plaster, but only for signaling systems. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U= 300/500 V, maximum permissible operating voltage, three-phase and alternating current Uo/U= 330/550 V, direct current Uo/U = 495/825 V, test AC voltage = 2000 V Installation note: When wiring in luminaires where the connection area of the wires is not protected against UV radiation and heat (generated by the light sources), a protective tube must generally be pushed over the exposed wires. Otherwise, depending on the switch-on duration, decomposition of the insulation will occur. Technical data Cable type H07V-U Cross-section 1.5mm² Color Black Nominal voltage 300/500V Standard VDE 0281
⚡ 1.5mm² Schwarz
EBROM HI-FLEX battery cable highly flexible 1.5mm² black 1,89 €
HIGHLY-Flexible EBROM battery cable type: HI-FLEX (also known as: Hi-Flex PVC Welding Cable) Easy to process and install due to the extremely flexible properties of the many copper strands and the special sheathing. 99.9% OFC full copper, highest quality level. Technical data Operating temperature: -30°C to +70°C fixed installation Operating temperature: +5°C to +70°C mobile use Please check the temperature of the place/area of use before application!! Minimum installation temperature: 0°C - Maximum temperature during short circuit +160°C at the conductor (max. duration 5 seconds) Protected installation is recommended! Not for use outdoors or in the ground Keep away from hot components and oils! Article class and specifications Article class: Core cable Conductor class: Cl. 5 = finely stranded Core insulation: PVC (70 ± 5 Shore) Nominal voltage: U0 450 V, U 750 V Standards according to: IEC 20-29 IEC 20-52 EN 60332-1 IEC 50265 Conductor material: copper, bare, 99.99% OFC For a finely stranded copper wire, the nominal cross-section cannot be reliably determined from the diameter of the wire bundle, not even with a caliper. Use the cable imprint or the data sheet. The circular area calculation using the circle formula A = π × d² / 4 applies to a solid, circular conductor. Sheath and insulation are not part of the conductor area. We are happy to help if you have any questions regarding classification. Technical data Cable type HI-FLEX Cross-section 1.5mm² Color Black
⚡ 1.5mm² Rot
EBROM H07V-K flexible single-core wire 1.5mm² red 0,48 €
H07V-K flexible wiring cable High-quality flexible stranded wiring cable. Technical information Fire behavior class according to EN 13501-6: Eca Flame-retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Class 5 = finely stranded Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Finely stranded VDE 0281 Application: In dry rooms, in equipment, switchgear and distribution boards, in conduits on or under plaster, as well as for protected installation in luminaires. Not permitted for: direct installation in plaster! Installation on trays, in channels (except for covered plastic channels) and similar. Approved for internal wiring of equipment for a mains voltage up to 1000 V AC and up to 750 V DC against earth. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U = 450/750 V Maximum permissible operating voltage: Three-phase and AC current Uo/U = 495/825 V; DC current Uo/U = 743/1238 V; Test AC voltage = 2500 V Installation instruction: When wiring in luminaires where the connection area of the cores is not protected from UV radiation and heat (caused by the light sources), a protective sleeve must always be pushed over the exposed cores. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H07V-K Cross-section 1.5mm² Colour Red
⚡ 1.5mm² Rot
EBROM H07V-U single-core wire rigid 1.5mm² red 0,48 €
H07V-U rigid wiring cable High-quality rigid wiring cable, ideal for fixed installation. Technical information Fire reaction class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Cl.1 = solid Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Cold-resistant according to EN 60811-504+505+506: Yes Solid VDE 0281 Application: for protected installation in equipment as well as in and on luminaires. Approved for installation in conduits on and under plaster, however, only for signal systems. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U= 300/500 V, maximum permissible operating voltage, three-phase and AC current Uo/U= 330/550 V, DC current Uo/U = 495/825 V, AC test voltage = 2000 V Installation note: For wiring in luminaires where the connection area of the wires is not protected from UV radiation and heat (caused by the light sources), a protective sleeve must always be slid over the exposed wires. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H07V-U Cross-section 1.5mm² Color Red Nominal voltage 300/500V Standard VDE 0281
⚡ 1.5mm² Rot
EBROM HI-FLEX Battery Cable highly flexible 1.5mm² Red 1,89 €
HIGHLY flexible EBROM battery cable Type: HI-FLEX (also known as: Hi-Flex PVC Welding Cable) Easy to process and install due to the extremely flexible properties of the many copper strands and the special sheathing. 99.9% OFC full copper, highest quality level. Technical data Operating temperature: -30° C to +70° fixed installation Operating temperature: +5° C to +70°C mobile use Please check the temperature of the place of use/area of application before use!! Minimum installation temperature: 0° C - Maximum temperature in case of short circuit + 160° C at the conductor (max. duration 5 seconds) Protected installation is recommended! Not for use outdoors or in the ground Keep away from hot components and oils! Article class and specifications Article class: Core wire Conductor class: Class 5 = finely stranded Core insulation: PVC (70 ± 5 Shore) Nominal voltage: U0 450 V, U 750 V Standards according to: IEC 20-29 IEC 20-52 EN 60332-1 IEC 50265 Conductor material: Copper, bare, 99.99% OFC With a finely stranded copper wire, the nominal cross-section cannot be reliably determined from the diameter of the wire bundle, not even with a caliper. Use the cable imprint or the data sheet. The circular area calculation using the circle formula A = π × d² / 4 applies to a solid, circular conductor. Sheath and insulation are not part of the conductor area. We are happy to help if you have any questions regarding classification. Technical data Cable type HI-FLEX Cross-section 1.5mm² Color Red
⚡ 1.5mm² Braun
EBROM H07V-K flexible wire 1.5mm² brown 0,48 €
H07V-K flexible wiring cable High-quality flexible stranded wiring cable. Technical information Reaction to fire class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Class 5 = finely stranded Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Finely stranded VDE 0281 Application: In dry rooms, in equipment, switchgear and distribution systems, in conduits on or under plaster, as well as for protected installation in light fixtures. Not permitted for: direct installation in plaster! Installation on trays, in cable ducts (except covered plastic ducts) and similar. Approved for internal wiring of equipment for a mains voltage up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U = 450/750 V Maximum permissible operating voltage: Three-phase and alternating current Uo/U = 495/825 V; Direct current Uo/U = 743/1238 V; AC test voltage = 2500 V Installation note: When wiring in light fixtures where the connection area of the wires is not protected against UV radiation and heat (caused by the illuminants), a protective sleeve must always be slid over the exposed wires. Otherwise, depending on the switch-on duration, decomposition of the insulation will occur. Technical data Cable type H07V-K Cross-section 1.5mm² Color Brown
⚡ 1.5mm² Braun
EBROM H07V-U single-core wire rigid 1.5mm² brown 0,48 €
H07V-U rigid wiring cable High-quality rigid wiring cable, ideal for fixed installation. Technical information Fire class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Cl.1 = single-wire Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Cold-resistant according to EN 60811-504+505+506: Yes Single-wire VDE 0281 Usage: for protected installation in equipment as well as in and on luminaires. Approved for installation in conduits on and under plaster, but only for signaling systems. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U= 300/500 V, maximum permissible operating voltage, three-phase and alternating current Uo/U= 330/550 V, direct current Uo/U = 495/825 V, test AC voltage = 2000 V Installation note: When wiring in luminaires where the connection area of the cores is not protected from UV radiation and heat (caused by the light sources), a protective sleeve must always be pushed over the exposed cores. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H07V-U Cross-section 1.5mm² Color Brown Nominal voltage 300/500V Standard VDE 0281
⚡ 1.5mm² Grau
EBROM H07V-K flexible single core wire 1.5mm² grey 0,48 €
H07V-K flexible wiring cable High-quality flexible stranded wiring cable. Technical information Fire behavior class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Class 5 = finely stranded Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Finely stranded VDE 0281 Application: In dry rooms, in equipment, switchgear and distribution systems, in conduits on or under plaster as well as for protected installation in luminaires. Not permitted for: direct installation in plaster! Installation on cable trays, in troughs (except for covered plastic troughs) and the like. Approved for the internal wiring of equipment for a mains voltage up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U = 450/750 V Maximum permissible operating voltage: Three-phase and AC current Uo/U = 495/825 V; DC current Uo/U = 743/1238 V; Test AC voltage = 2500 V Installation note: When wiring luminaires where the connection area of the wires is not protected from UV radiation and heat (caused by the illuminants), a protective sleeve must always be pushed over the exposed wires. Otherwise, decomposition of the insulation will occur depending on the switch-on time. Technical data Cable type H07V-K Cross-section 1.5mm² Color Gray

Free standard shipping to Germany from €60

Fast shipping within Germany

In-house German assembly

Cable assemblies from our own production

Specialist Consulting

Consultation by phone at +49 8074 9176911
PayPal Visa Mastercard SEPA Klarna