⚡ 0.75mm² Grau
EBROM H05V-K flexible single-core cable 0.75mm² grey 0,40 €
Single-core stranded wire, fine-wired cores of class 5 according to VDE 0281, for use in dry rooms, in devices, switchgear and distribution boards, in conduits on and under plaster, as well as in closed installation ducts. For protected installation in and on lighting fixtures. In and on electronic equipment in power systems for measuring, control, and regulation purposes. Not permitted for direct installation under plaster. Approved for internal wiring of devices for a mains voltage up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC current Uo/U = 330/550 V; direct current Uo/U = 495/825 V; test AC voltage = 2000 V - Installation note: For wiring in lighting fixtures where the core connection area is not protected from UV radiation and heat (caused by the illuminants), a protective sleeve must always be pushed over the exposed cores. Otherwise, degradation of the insulation will occur depending on the operating time. Technical data Cable type H05V-K Cross-section 0.75mm² Color Grey Nominal voltage 300/500V Standard VDE 0281
⚡ 0.75mm² Weiss
EBROM H05V-K flexible single-core wire 0.75mm² white 0,40 €
Multi-strand single core, fine-wired cores of core class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear and distribution boards, in conduits on and under plaster, as well as in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power systems for the purpose of measuring, controlling and regulating. Not permitted for direct installation under plaster. For the internal wiring of equipment, approved for a mains voltage of up to 1000 V AC and up to 750 V DC against earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC current Uo/U = 330/550 V; direct current Uo/U = 495/825 V; test AC voltage = 2000 V - Installation note: When wiring luminaires where the connection area of the cores is not protected against UV radiation and heat (generated by the lamps), a protective sleeve must always be pushed over the exposed cores. Otherwise, decomposition of the insulation will occur depending on the duty cycle. Technical data Cable type H05V-K Cross-section 0.75mm² Colour White Nominal voltage 300/500V Standard VDE 0281
⚡ 0.75mm² Gelb
EBROM H05V-K flexible wire 0.75mm² yellow 0,40 €
Single-core stranded wire, fine-wired cores of class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear and distribution boards, in conduits on and under plaster, and in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power installations for the purpose of measuring, controlling and regulating. Not permitted for direct installation under plaster. For the internal wiring of equipment, approved for a mains voltage of up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and alternating current Uo/U = 330/550 V; direct current Uo/U = 495/825 V; test AC voltage = 2000 V - Installation note: When wiring luminaires where the connection area of the wires is not protected from UV radiation and heat (caused by the lamps), a protective sleeve must always be pushed over the exposed wires. Otherwise, decomposition of the insulation will occur depending on the operating time. Technical data Cable type H05V-K Cross-section 0.75mm² Colour Yellow Nominal voltage 300/500V Standard VDE 0281
⚡ 0.75mm² Grün
EBROM H05V-K flexible single-core wire 0.75mm² green 0,40 €
Single-core stranded wire, fine-stranded conductors of conductor class 5 according to VDE 0281, for use in dry rooms, in devices, switchgear and distribution boards, in conduits on and under plaster, and in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power installations for the purpose of measuring, controlling and regulating. Not permitted for direct installation under plaster. Approved for the internal wiring of equipment for mains voltages up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC current Uo/U = 330/550 V; direct current Uo/U = 495/825 V; AC test voltage = 2000 V - Installation note: When wiring in luminaires where the connection area of the wires is not protected from UV radiation and heat (generated by the lamps), a protective sleeve must be placed over the exposed wires. Otherwise, depending on the switch-on duration, the insulation will decompose. Technical data Cable type H05V-K Cross-section 0.75mm² Colour Green Nominal voltage 300/500V Standard VDE 0281
⚡ 0.75mm² Orange
EBROM H05V-K flexible single-core cable 0.75mm² orange 0,40 €
Single-core stranded, fine-wired conductors of conductor class 5 according to VDE 0281, for use in dry rooms, in devices, switchgear and distribution boards, in conduits on and under plaster, as well as in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power installations for the purpose of measuring, controlling, and regulating. Not permitted for direct installation under plaster. For internal wiring of devices, approved for mains voltages up to 1000 V AC and up to 750 V DC against earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC current Uo/U = 330/550 V; DC current Uo/U = 495/825 V; Test AC voltage = 2000 V - Installation note: For wiring in luminaires where the connection area of the wires is not protected from UV radiation and heat (generated by the bulbs), a protective sleeve must be placed over the exposed wires as a general rule. Otherwise, the insulation will decompose depending on the duration of operation. Technical data Cable type H05V-K Cross-section 0.75mm² Color Orange Nominal voltage 300/500V Standard VDE 0281
⚡ 0.75mm² Violett
EBROM H05V-K flexible conductor 0.75mm² violet 0,40 €
Single-core stranded, fine-stranded conductors of conductor class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear and distribution boards, in conduits on and under plaster, as well as in closed installation ducts. For protected installation in and on lighting fixtures. In and on electronic equipment in power installations for measuring, control, and regulation purposes. Not permitted for direct installation under plaster. For internal wiring of equipment, approved for a mains voltage up to 1000 V AC and up to 750 V DC against earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC Uo/U = 330/550 V; DC Uo/U = 495/825 V; AC test voltage = 2000 V - Installation instruction: When wiring in lighting fixtures where the conductor connection area is not protected from UV radiation and heat (caused by the illuminants), a protective sleeve must always be slid over the exposed conductors. Otherwise, decomposition of the insulation will occur depending on the duty cycle. Technical Data Cable type H05V-K Cross-section 0.75mm² Colour Violet Nominal voltage 300/500V Standard VDE 0281
⚡ 0.75mm² Hellblau
EBROM H05V-K flexible single-core wire 0.75mm² light blue 0,40 €
Single-core stranded, fine-wired conductors of conductor class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear and distribution boards, in conduits on and under plaster, as well as in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power installations for the purpose of measuring, controlling, and regulating. Not permitted for direct installation under plaster. Approved for the internal wiring of equipment with a mains voltage of up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC voltage Uo/U = 330/550 V; DC voltage Uo/U = 495/825 V; AC test voltage = 2000 V - Installation instruction: When wiring in luminaires where the connection area of the wires is not protected from UV radiation and heat (caused by the illuminants), a protective tube must always be pushed over the exposed wires. Otherwise, decomposition of the insulation will occur depending on the operating time. Technical data Cable type H05V-K Cross-section 0.75mm² Color Light blue Nominal voltage 300/500V Standard VDE 0281
⚡ 0.75mm² Dunkelblau
EBROM H05V-K flexible core wire 0.75mm² dark blue 0,40 €
Single-core stranded, fine-wired conductors of conductor class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear and distribution boards, in conduits on and under plaster, as well as in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power installations for the purpose of measuring, controlling and regulating. Not permitted for direct installation under plaster. For the internal wiring of equipment approved for mains voltage up to 1000 V AC and up to 750 V DC against earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC Uo/U = 330/550 V; DC Uo/U = 495/825 V; Test AC voltage = 2000 V - Installation note: When wiring in luminaires where the connection area of the wires is not protected against UV radiation and heat (caused by the illuminants), a protective sleeve must always be pushed over the exposed wires. Otherwise, decomposition of the insulation will occur depending on the operating time. Technical data Cable type H05V-K Cross-section 0.75mm² Colour Dark blue Nominal voltage 300/500V Standard VDE 0281
⚡ 0.75mm² Grün/Gelb
EBROM H05V-K flexible single-core wire 0.75mm² green/yellow 0,40 €
Single-core stranded wire, fine-stranded conductor class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear, and distribution boards, in conduits on and under plaster, as well as in closed installation ducts. For protected installation in and on lighting fixtures. In and on electronic equipment in power installations for measuring, control, and regulation purposes. Not permitted for direct installation under plaster. For internal wiring of equipment, approved for a mains voltage of up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Rated voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC voltage Uo/U = 330/550 V; DC voltage Uo/U = 495/825 V; Test AC voltage = 2000 V - Installation note: When wiring in lighting fixtures where the connection area of the wires is not protected from UV radiation and heat (caused by the light sources), a protective sleeve must be placed over the exposed wires. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H05V-K Cross-section 0.75mm² Colour Green/Yellow Rated voltage 300/500V Standard VDE 0281
⚡ 1.0mm² Schwarz
EBROM H05V-K flexible single-core cable 1.0mm² black 0,47 €
Single-core stranded, fine-stranded conductors of conductor class 5 according to VDE 0281, for use in dry rooms, in devices, switchgear and distributors, in pipes on and under plaster as well as in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power installations for the purpose of measuring, controlling and regulating. Not permitted for direct installation under plaster. Approved for the internal wiring of devices for a mains voltage up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and alternating current Uo/U = 330/550 V; direct current Uo/U = 495/825 V; test alternating voltage = 2000 V - Installation note: When wiring in luminaires where the connection area of the conductors is not protected from UV radiation and heat (caused by the illuminants), a protective tube must always be pushed over the exposed conductors. Otherwise, decomposition of the insulation will occur depending on the duty cycle. Technical data Cable type H05V-K Cross-section 1.0mm² Colour Black Nominal voltage 300/500V Standard VDE 0281
⚡ 1.0mm² Rot
EBROM H05V-K flexible single-core wire 1.0mm² red 0,47 €
Single-core stranded wire, fine-stranded conductor class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear and distribution boards, in conduits on and under plaster, as well as in closed installation ducts. For protected installation in and on light fixtures. In and on electronic equipment in power installations for measuring, control and regulation purposes. Not permitted for direct installation under plaster. Approved for the internal wiring of equipment with a mains voltage of up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC current Uo/U = 330/550 V; direct current Uo/U = 495/825 V; AC test voltage = 2000 V - Installation note: When wiring light fixtures where the connection area of the wires is not protected against UV radiation and heat (caused by the lamps), a protective sleeve must always be slid over the exposed wires. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H05V-K Cross-section 1.0mm² Color Red Nominal voltage 300/500V Standard VDE 0281
⚡ 1.0mm² Braun
EBROM H05V-K flexible wire 1.0mm² brown 0,47 €
Single-core stranded wire, fine-stranded conductors of conductor class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear and distribution boards, in conduits on and under plaster, and in closed installation ducts. For protected installation in and on light fittings. In and on electronic equipment in power installations for the purpose of measuring, controlling and regulating. Not permitted for direct installation under plaster. Approved for internal wiring of equipment for mains voltages up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC Uo/U = 330/550 V; DC Uo/U = 495/825 V; Test AC voltage = 2000 V - Installation instruction: When wiring in light fittings where the connection area of the wires is not protected from UV radiation and heat (generated by the bulbs), a protective sleeve must always be pushed over the exposed wires. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H05V-K Cross-section 1.0mm² Colour Brown Nominal voltage 300/500V Standard VDE 0281
⚡ 1.0mm² Grau
EBROM H05V-K flexible core wire 1.0mm² grey 0,47 €
Single-core stranded, fine-wired conductors of conductor class 5 according to VDE 0281, for use in dry rooms, in devices, switchgear and distributors, in pipes on and under plaster as well as in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power installations for the purpose of measuring, controlling and regulating. Not permitted for direct installation under plaster. For internal wiring of equipment approved for a mains voltage of up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC current Uo/U = 330/550 V; DC current Uo/U = 495/825 V; Test AC voltage = 2000 V - Installation note: When wiring in luminaires where the connection area of the wires is not protected from UV radiation and heat (caused by the illuminants), a protective tube must always be pushed over the exposed wires. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H05V-K Cross-section 1.0mm² Colour Grey Nominal voltage 300/500V Standard VDE 0281
⚡ 1.0mm² Weiss
EBROM H05V-K flexible single-core wire 1.0mm² white 0,47 €
Single-core stranded, finely stranded conductors of conductor class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear and distributors, in conduits on and under plaster, as well as in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power installations for the purpose of measuring, controlling, and regulating. Not permitted for direct installation under plaster. Approved for the internal wiring of equipment with a mains voltage up to 1000 V AC and up to 750 V DC against earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC Uo/U = 330/550 V; DC Uo/U = 495/825 V; Test AC voltage = 2000 V - Installation note: When wiring in luminaires where the connection area of the cores is not protected from UV radiation and heat (caused by the light sources), a protective sleeve must always be pushed over the exposed cores. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H05V-K Cross-section 1.0mm² Colour White Nominal voltage 300/500V Standard VDE 0281
⚡ 1.0mm² Gelb
EBROM H05V-K flexible core cable 1.0mm² yellow 0,47 €
Single-core stranded wire, fine-stranded conductor of conductor class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear and distribution boards, in conduits on and under plaster, as well as in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power installations for the purpose of measuring, controlling and regulating. Not permitted for direct installation under plaster. Approved for internal wiring of equipment for a mains voltage up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 300/500 V - Maximum permissible operating voltage: Three-phase and AC current Uo/U = 330/550 V; DC current Uo/U = 495/825 V; Test AC voltage = 2000 V - Installation note: When wiring luminaires where the connection area of the wires is not protected from UV radiation and heat (generated by the lamps), a protective sleeve must always be pushed over the exposed wires. Otherwise, decomposition of the insulation will occur depending on the operating time. Technical data Cable type H05V-K Cross-section 1.0mm² Color Yellow Nominal voltage 300/500V Standard VDE 0281

Free standard shipping to Germany from €60

Fast shipping within Germany

In-house German assembly

Cable assemblies from our own production

Specialist Consulting

Consultation by phone at +49 8074 9176911
PayPal Visa Mastercard SEPA Klarna