⚡ 5x16mm² Grau
EBROM NYM-J Installation Cable 5x16mm² Grey 24,29 €
Sheathed cable/installation cable with copper conductor 5x16mm². Suitable for installation in homes, industry, outdoors, in dry and damp rooms, on, in, and under plaster, in masonry and concrete (excluding vibrated, shaken, or tamped concrete). --- For outdoor use, the cable must be protected from direct sunlight. Technical data Cable type NYM-J Cross-section 5x16mm² Colour Grey
⚡ 5x16mm² Grau
EBROM YSLY-JB Installation Cable Flexible 5x16mm² Gray 27,33 €
Installation cable, including for the supply of EV charging stations. Highly flexible 5x16 mm². The cable of choice for many electricians for the supply line to your charging station. The annoyances of a cable that is too rigid are a thing of the past. Thanks to its flexible properties, this cable is wonderful to lay. Suitable for installation in dry and damp rooms. Thermal resistance and extensive resistance to oil, petrol, alkalis, greases, chemicals, etc. Design based on VDE decision no. 41, VDE 0250, 0271, 0281 and 0293; finely stranded, bare copper wire according to VDE 0295, PVC core insulation, outer sheath material: PVC, color: gray - Technical data: operating voltage max. 500 V, test voltage eff. 2000 V, breakdown voltage >5 kV, insulation resistance min. 20 MΩ/km, temperature range: moved -5 °C to +80 °C, fixed -20 °C to +80 °C, minimum bending radius: for fixed installation: 6 x outer diameter, for mobile use: 15x outer diameter – APPLICATION EXAMPLES: Industry: The cable can be used as a supply line for machines and systems. - Building services: It can be used for wiring electrical circuits in buildings - Event technology: The cable is well suited for use in event technology, for example for the power supply of stage and lighting equipment - Solar systems: The cable can also be used as a supply line for solar systems to feed the generated electricity into the power grid - Shipbuilding and boat building: It can also be used in the shipbuilding and boat building industry, for example for the power supply of engines or electrical systems on board ---SAFETY NOTE--- According to DIN VDE 0100-520, flexible cables such as YSLY are permitted for fixed installation, provided they are housed throughout in conduits or equivalent protective measures. If protective measures against mechanical damage are not observed, use is not permitted Technical data Cable type YSLY-JB Cross-section 5x16mm² Color Gray Standard VDE 0250 Temperature range -5°C to +80°C
⚡ 5x25mm² Grau
EBROM NYM-J Installation Cable 5x25mm² Grey 37,24 €
Sheathed cable/installation cable with copper conductor 5x25mm² Suitable for installation in homes, industry, outdoors, in dry and damp rooms, on, in and under plaster, in masonry and in concrete (except for vibrated or tamped concrete). --- For outdoor use, the cable must be protected from direct sunlight. Technical data Cable type NYM-J Cross-section 5x25mm² Colour Grey
⚡ 5x35mm² Grau
EBROM NYM-J Installation Cable 5x35mm² Grey 48,58 €
Sheathed cable/installation cable with copper conductor 5x35mm². Suitable for installation in homes, in industry, outdoors, in dry and damp rooms, on, in and under plaster, in masonry and in concrete (excluding vibrated, shaken or tamped concrete). --- For outdoor use, the cable must be protected from direct sunlight. Technical data Cable type NYM-J Cross-section 5x35mm² Color Grey
⚡ 7x1.5mm² Grau
EBROM NYM-J Installation Cable 7x1.5mm² Grey 3,95 €
Sheathed cable/installation cable with copper conductor 7x1.5mm². Suitable for installation in homes, industry, outdoors, in dry and damp rooms, on, in, and under plaster, in masonry, and in concrete (excluding vibrated, shaken, or tamped concrete). --- For outdoor use, the cable must be protected from direct sunlight. 6 of the 7 cores are numbered to assist you with identification during connection. Green/yellow is color-coded. Technical data Cable type NYM-J Cross-section 7x1.5mm² Color Gray
⚡ 7x1.5mm² Farbige Adern
EBROM NYM-J Installation Cable 7x1.5mm² Colored Cores 6,69 €
Sheathed cable/installation cable with copper conductor 7x1.5 mm² sheathed cable VDE 0281, Part 204. Application: For installation over, on, in, and under plaster in dry, damp, and wet rooms as well as in masonry and concrete, excluding direct embedding in vibrated, shaken, or tamped concrete. Also suitable for outdoor use if protected from direct sunlight, but not for underground use. Temperature range: maximum conductor temperature 70° C, Technical data: - Nominal voltage Uo/U = 500 V. Maximum permissible operating voltage - Three-phase current Uo/U = 575 V, - Direct and single-phase alternating current Uo/U - ungrounded = 575 V, - grounded = 330 V, - Test AC voltage = 2000 V. Minimum bending radius: 4 x D (cable diameter). Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2, outer diameter approx. 11 mm Technical data Cable type NYM-J Cross-section 7x1.5mm² Colour Coloured cores
⚡ 7x2.5mm² Grau
EBROM NYM-J Installation Cable 7x2.5mm² Grey 6,07 €
Sheathed cable/installation cable with copper conductor 7x2.5mm² Suitable for installation in households, industry, outdoors, in dry and damp rooms, on, in and under plaster, in masonry and in concrete (excluding vibrated, shaken or tamped concrete). --- For outdoor use, the cable must be protected from direct sunlight. 6 out of 7 wires are numbered to assist you with identification during connection. Green/yellow is color-coded. Technical data Cable type NYM-J Cross-section 7x2.5mm² Color Gray

Free standard shipping to Germany from €60

Fast shipping within Germany

In-house German assembly

Cable assemblies from our own production

Specialist Consulting

Consultation by phone at +49 8074 9176911