⚡ 2.5mm² Orange
EBROM H07V-K flexible single-core wire 2.5mm² orange 0,72 €
Single-core stranded, fine-stranded conductor, class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear and distribution boards, in conduits on or under plaster, as well as in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power systems for measuring, control and regulation purposes. Not permitted for direct installation under plaster. Approved for the internal wiring of equipment up to a mains voltage of 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 450/750 V - Maximum permissible operating voltage: Three-phase and AC Uo/U = 495/825 V; DC Uo/U = 743/1238 V; Test AC voltage = 2500 V - Installation note: When wiring luminaires where the connection area of the wires is not protected from UV radiation and heat (caused by the light sources), a protective sleeve must always be pushed over the exposed wires. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H07V-K Cross-section 2.5mm² Colour Orange
⚡ 2.5mm² Violett
EBROM H07V-K flexible single-core wire 2.5mm² violet 0,72 €
Stranded single core, class 5 fine-stranded wires according to VDE 0281, for use in dry rooms, in equipment, switchgear and distribution boards, in conduits on and under plaster, as well as in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power installations for measuring, controlling and regulating. Not permitted for direct installation under plaster. Approved for the internal wiring of equipment for mains voltages up to 1000 V AC and 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 450/750 V - Maximum permissible operating voltage: Three-phase and AC voltage Uo/U = 495/825 V; DC voltage Uo/U = 743/1238 V; Test AC voltage = 2500 V - Installation note: When wiring luminaires where the connection area of the wires is not protected from UV radiation and heat (generated by the light source), a protective sleeve must always be pushed over the exposed wires. Otherwise, degradation of the insulation will occur depending on the operating time. Technical data Cable type H07V-K Cross-section 2.5mm² Colour Violet
⚡ 2.5mm² Violett
EBROM H07V-U single-core wire rigid 2.5mm² violet 0,72 €
H07V-U rigid installation wire High-quality rigid installation wire, ideal for fixed installation. Technical information Fire behavior class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Cl.1 = single-wire Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Cold-resistant according to EN 60811-504+505+506: Yes Single-wire VDE 0281 Usage: for protected installation in equipment as well as in and on light fittings. Approved for installation in conduits on and under plaster, but only for signaling systems. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U= 300/500 V, maximum permissible operating voltage, three-phase and AC current Uo/U= 330/550 V, DC current Uo/U = 495/825 V, AC test voltage = 2000 V Installation note: When wiring light fittings where the connection area of the wires is not protected from UV radiation and heat (caused by the light sources), a protective sleeve must always be slid over the exposed wires. Otherwise, degradation of the insulation will occur depending on the operating time. Technical data Cable type H07V-U Cross-section 2.5mm² Color Violet Nominal voltage 300/500V Standard VDE 0281
⚡ 2.5mm² Hellblau
EBROM H07V-K flexible single core wire 2.5mm² light blue 0,72 €
Single-core stranded wire, fine-stranded conductor class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear and distribution boards, in conduits on and under plaster, and in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment in power systems for measuring, control, and regulation purposes. Not permitted for direct installation under plaster. For internal wiring of devices, approved for mains voltages up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 450/750 V - Maximum permissible operating voltage: Three-phase and AC Uo/U = 495/825 V; DC Uo/U = 743/1238 V; Test AC voltage = 2500 V - Installation note: When wiring in luminaires where the connection area of the wires is not protected from UV radiation and heat (generated by the lamps), a protective sleeve must always be pushed over the exposed wires. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H07V-K Cross-section 2.5mm² Color Light blue
⚡ 2.5mm² Hellblau
EBROM H07V-U single-core wire rigid 2.5mm² light blue 0,72 €
H07V-U rigid installation wire High-quality rigid installation wire, ideal for fixed installation. Technical information Fire behavior class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Class 1 = single-wire Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Cold-resistant according to EN 60811-504+505+506: Yes Single-wire VDE 0281 Application: for protected installation in equipment as well as in and on luminaires. Approved for installation in conduits on and under plaster, but only for signal systems. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U= 300/500 V, maximum permissible operating voltage, three-phase and AC current Uo/U= 330/550 V, DC current Uo/U = 495/825 V, test AC voltage = 2000 V Installation note: When wiring luminaires where the connection area of the wires is not protected from UV radiation and heat (generated by the light sources), a protective sleeve must always be pushed over the exposed wires. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H07V-U Cross-section 2.5mm² Color Light blue Nominal voltage 300/500V Standard VDE 0281
⚡ 2.5mm² Dunkelblau
EBROM H07V-K flexible single-core cable 2.5mm² dark blue 0,72 €
H07V-K flexible wiring cable High-quality flexible multi-strand wiring cable. Technical information Reaction to fire class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Class 5 = fine-stranded Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Fine-stranded VDE 0281 Application: In dry rooms, in equipment, switchgear and distribution cabinets, in conduits on or under plaster as well as for protected installation in luminaires. Not permitted for: direct installation in plaster! Installation on cable trays, in troughs (except for covered plastic troughs) and the like. For the internal wiring of equipment, approved for a mains voltage up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U = 450/750 V Maximum permissible operating voltage: Three-phase and alternating current Uo/U = 495/825 V; Direct current Uo/U = 743/1238 V; AC test voltage = 2500 V Installation note: When wiring in luminaires where the connection area of the cores is not protected from UV radiation and heat (caused by the light sources), a protective sleeve must always be slid over the exposed cores. Otherwise, insulation decomposition will occur depending on the duty cycle. Technical data Cable type H07V-K Cross-section 2.5mm² Colour Dark blue
⚡ 2.5mm² Grün/Gelb
EBROM H07V-K flexible single-core wire 2.5mm² Green/Yellow 0,72 €
Single-core stranded, finely stranded conductors of conductor class 5 according to VDE 0281, for use in dry rooms, in equipment, switchgear and distribution boards, in conduits on and under plaster, and in closed installation ducts. For protected installation in and on luminaires. In and on electronic equipment for power installations for the purpose of measuring, controlling and regulating. Not permitted for direct installation under plaster. For the internal wiring of equipment, approved for a mains voltage up to 1000 V AC and up to 750 V DC against earth. Temperature range: maximum conductor temperature 70 °C - Technical data: Nominal voltage Uo/U = 450/750 V - Maximum permissible operating voltage: Three-phase and AC current Uo/U = 495/825 V; DC current Uo/U = 743/1238 V; Test AC voltage = 2500 V - Installation note: When wiring in luminaires where the connection area of the wires is not protected from UV radiation and heat (caused by the illuminants), a protective tube must always be pushed over the exposed wires. Otherwise, decomposition of the insulation will occur depending on the duty cycle. Technical data Cable type H07V-K Cross-section 2.5mm² Colour Green/Yellow
⚡ 2.5mm² Grün/Gelb
EBROM H07V-U single-core wire rigid 2.5mm² Green/Yellow 0,72 €
H07V-U rigid wiring cable High-quality rigid wiring cable, ideal for fixed installation. Technical information Reaction to fire class according to EN 13501-6: Eca Flame-retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Cl.1 = single-wire Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Cold-resistant according to EN 60811-504+505+506: Yes Single-wire VDE 0281 Usage: for protected installation in equipment as well as in and on luminaires. Approved for installation in conduits on and under plaster, but only for signal systems. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U= 300/500 V, maximum permissible operating voltage, three-phase and alternating current Uo/U= 330/550 V, direct current Uo/U = 495/825 V, AC test voltage = 2000 V Installation note: When wiring luminaires where the connection area of the wires is not protected from UV radiation and heat (caused by the illuminants), a protective sleeve must always be pushed over the exposed wires. Otherwise, decomposition of the insulation will occur depending on the duty cycle. Technical data Cable type H07V-U Cross-section 2.5mm² Color Green/Yellow Nominal voltage 300/500V Standard VDE 0281
⚡ 4mm² Schwarz
EBROM H07V-K flexible single-core wire 4mm² black 1,84 €
H07V-K flexible wiring cable High-quality flexible stranded wiring cable. Technical information Reaction to fire class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Class 5 = fine-stranded Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Fine-stranded VDE 0281 Application: In dry rooms, in equipment, switchgear and distribution boards, in conduits on or under plaster, as well as for protected installation in light fixtures. Not permitted for: direct installation in plaster! Installation on cable trays, in troughs (except covered plastic troughs) and similar. Approved for internal wiring of devices for a mains voltage up to 1000 V AC and up to 750 V DC against earth. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U = 450/750 V Maximum permissible operating voltage: Three-phase and AC current Uo/U = 495/825 V; DC current Uo/U = 743/1238 V; Test AC voltage = 2500 V Installation note: When wiring in light fixtures where the connection area of the wires is not protected from UV radiation and heat (caused by the light sources), a protective sleeve must always be slid over the exposed wires. Otherwise, decomposition of the insulation will occur depending on the operating time. Technical data Cable type H07V-K Cross-section 4mm² Color Black
⚡ 4mm² Schwarz
EBROM H07V-U single-core wire rigid 4mm² black 1,31 €
H07V-U rigid wiring cable High-quality rigid wiring cable, ideal for fixed installation. Technical information Reaction to fire class according to EN 13501-6: Eca Flame-retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Cl.1 = single-wire Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Cold-resistant according to EN 60811-504+505+506: Yes Single-wire VDE 0281 Usage: for protected installation in equipment as well as in and on luminaires. Approved for installation in conduits on and under plaster, but only for signal systems. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U= 300/500 V, maximum permissible operating voltage, three-phase and AC current Uo/U= 330/550 V, DC current Uo/U = 495/825 V, AC test voltage = 2000 V Installation note: When wiring in luminaires where the connection area of the cores is not protected from UV radiation and heat (caused by the illuminants), a protective tube must always be pushed over the exposed cores. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H07V-U Cross-section 4mm² Color Black Nominal voltage 300/500V Standard VDE 0281
⚡ 4mm², Schwarz
EBROM HI-FLEX battery cable, highly flexible, 4mm², black 5,43 €
HIGHLY flexible EBROM battery cable type: HI-FLEX (also known as: Hi-Flex PVC Welding Cable) Easy to process and lay due to the extremely flexible properties of the many copper strands and the special sheathing. 99.9% OFC full copper, highest quality level. Technical data Operating temperature: -30° C to +70° C fixed installation Operating temperature: +5° C to +70° C mobile use Please check the temperature of the place of use/area of application before use!! Minimum installation temperature: 0° C - Maximum temperature in case of short circuit + 160° C at the conductor (max. duration 5 seconds) Protected installation is recommended! Not for use outdoors or in the ground Keep away from hot components and oils! Article class and specifications Article class: Core cable Conductor class: Class 5 = finely stranded Core insulation: PVC (70 ± 5 Shore) Nominal voltage: U0 450 V, U 750 V Standards according to: IEC 20-29 IEC 20-52 EN 60332-1 IEC 50265 Conductor material: Copper, bare, 99.99% OFC With a finely stranded copper wire, the nominal cross-section cannot be reliably determined from the diameter of the wire bundle, not even with a caliper. Use the cable imprint or the data sheet. The circular area calculation using the circle formula A = π × d² / 4 applies to a solid, circular conductor. Sheath and insulation are not part of the conductor area. We are happy to help if you have any questions regarding classification. Technical data Cable type HI-FLEX Cross-section 4mm² Color Black
⚡ 4mm² Rot
EBROM H07V-K flexible single-core wire 4mm² red 1,84 €
Battery cable for many areas of application - 99.9% OFC copper - sold by the meter according to customer requirements - various cross-sections - With fine-stranded copper wire, the nominal cross-section cannot be reliably determined from the diameter of the wire bundle, not even with a caliper. Please use the cable imprint or the data sheet. The circular area calculation using the circle formula A = π × d² / 4 applies to a solid, circular conductor. The sheath and insulation are not part of the conductor area. If you have any questions regarding identification, we are happy to help. Technical Data Cable type H07V-K Cross-section 4mm² Color Red
⚡ 4mm², Rot
EBROM HI-FLEX battery cable, highly flexible, 4mm², red 5,43 €
HIGHLY flexible EBROM battery cable Type: HI-FLEX (also known as: Hi-Flex PVC Welding Cable) Easy to process and install due to the extremely flexible properties of the many copper strands and the special sheathing. 99.9% OFC full copper, highest quality level. Technical data Operating temperature: -30°C to +70°C for fixed installation Operating temperature: +5°C to +70°C for mobile use Please check the temperature of the place of use/area of application before use!! Minimum installation temperature: 0°C - Maximum temperature in case of short circuit + 160°C at the conductor (max. duration 5 seconds) Protected installation is recommended! Not for use outdoors or in the ground Keep away from hot components and oils! Article class and specifications Article class: Core cable Conductor class: Class 5 = fine-stranded Core insulation: PVC (70 ± 5 Shore) Nominal voltage: U0 450 V, U 750 V Standards according to: IEC 20-29 IEC 20-52 EN 60332-1 IEC 50265 Conductor material: Copper, bare, 99.99% OFC With a fine-stranded copper wire, the nominal cross-section cannot be reliably determined from the diameter of the wire bundle, not even with a caliper. Use the cable imprint or the data sheet. The circular area calculation using the circle formula A = π × d² / 4 applies to a solid, circular conductor. The sheath and insulation are not part of the conductor area. We are happy to help if you have any questions regarding classification. Technical data Cable type HI-FLEX Cross-section 4mm² Color Red
⚡ 4mm² Blau
EBROM H07V-K flexible single-core wire 4mm² blue 1,84 €
Flexible EBROM battery cable, type H07V-K. Easy to process and install due to the flexible properties of the many copper strands. 99.9% OFC full copper, highest quality level. Technical data: Max. operating temperature (fixed installation): -30°C to +80°C. Max. operating temperature (moved): -5°C to +70°C. Please check the temperature of the place of use/area of application before use!! Protected installation is recommended! Keep away from hot components and oils! Article class and specifications: Article class: Core wire. Conductor class: Class 5 = fine-stranded. Core insulation: PVC. Nominal voltage: U0 450 V, U 750 V. Conductor material: Copper, bare, 99.99% OFC. With a fine-stranded copper wire, the nominal cross-section cannot be reliably determined from the diameter of the wire bundle, even with a caliper gauge. Please use the cable imprint or the data sheet. The circular area calculation using the circle formula A = π × d² / 4 applies to a solid, circular conductor. Sheath and insulation are not part of the conductor area. We are happy to help if you have any questions regarding classification. Technical data Cable type H07V-K Cross-section 4mm² Color Blue
⚡ 4mm² Braun
EBROM H07V-K flexible core wire 4mm² brown 1,84 €
H07V-K flexible wiring cable High-quality flexible multi-strand wiring cable. Technical information Fire reaction class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Class 5 = fine-stranded Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Fine-stranded VDE 0281 Application: In dry rooms, in equipment, switchgear and distribution cabinets, in conduits on or under plaster as well as for protected installation in luminaires. Not permitted for: direct installation in plaster! Installation on cable trays, in troughs (except for covered plastic troughs) and the like. Approved for the internal wiring of devices for a mains voltage up to 1000 V AC and up to 750 V DC against earth. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U = 450/750 V Maximum permissible operating voltage: Three-phase and AC current Uo/U = 495/825 V; DC current Uo/U = 743/1238 V; Test AC voltage = 2500 V Installation note: When wiring in luminaires where the connection area of the wires is not protected from UV radiation and heat (caused by the light sources), a protective sleeve must always be slid over the exposed wires. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H07V-K Cross-section 4mm² Colour Brown

Free standard shipping to Germany from €60

Fast shipping within Germany

In-house German assembly

Cable assemblies from our own production

Specialist Consulting

Consultation by phone at +49 8074 9176911
PayPal Visa Mastercard SEPA Klarna