⚡ 4mm² Braun
EBROM H07V-U single-core wire rigid 4mm² brown 1,31 €
H07V-U rigid wiring cable High-quality rigid wiring cable, ideal for fixed installation. Technical information Fire behavior class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Cl.1 = single-wire Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Cold-resistant according to EN 60811-504+505+506: Yes Single-wire VDE 0281 Application: for protected installation in equipment as well as in and on luminaires. Approved for installation in conduits on and under plaster, but only for signal systems. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U= 300/500 V, maximum permissible operating voltage, three-phase and AC current Uo/U= 330/550 V, DC current Uo/U = 495/825 V, test AC voltage = 2000 V Installation note: When wiring in luminaires where the connection area of the cores is not protected from UV radiation and heat (caused by the illuminants), a protective tube must always be pushed over the exposed cores. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H07V-U Cross-section 4mm² Color Brown Nominal voltage 300/500V Standard VDE 0281
⚡ 4mm² Grau
EBROM H07V-K flexible single-core cable 4mm² grey 1,84 €
H07V-K flexible wiring cable High-quality flexible stranded wiring cable. Technical information Reaction to fire class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Class 5 = finely stranded Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Finely stranded VDE 0281 Application: In dry rooms, in equipment, switchgear and distribution systems, in conduits on or under plaster, and for protected installation in luminaires. Not permitted for: direct installation in plaster! Installation on cable trays, in troughs (except for covered plastic troughs) and the like. Approved for the internal wiring of equipment for a mains voltage of up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U = 450/750 V Maximum permissible operating voltage: Three-phase and AC current Uo/U = 495/825 V; DC current Uo/U = 743/1238 V; Test AC voltage = 2500 V Installation note: For wiring in luminaires where the connection area of the cores is not protected against UV radiation and heat (generated by the light sources), a protective sleeve must always be slid over the exposed cores. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H07V-K Cross-section 4mm² Colour Grey
⚡ 4mm² Grau
EBROM NYM-J Installation Cable 4mm² Grey 1,83 €
Earthing cable - not an underground cable! - GRAY with 100% OFC copper conductor, rigid single core, according to STANDARD - sheathed cable VDE 0281, Part 204. Use: Installation above, on, in and under plaster in dry, damp and wet rooms as well as in masonry and concrete, except for direct embedding in vibrated, shaken or tamped concrete. Also suitable for outdoor use, provided it is protected from direct sunlight, but not for underground use. Technical data Cable type NYM-J Cross-section 4mm² Color Gray
⚡ 4mm² Hellblau
EBROM H07V-K flexible single core wire 4mm² light blue 1,84 €
H07V-K flexible wiring cable High-quality flexible multi-stranded wiring cable. Technical information Reaction to fire class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Cl.5 = fine-stranded Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Fine-stranded VDE 0281 Use: In dry rooms, in equipment, switchgear and distribution cabinets, in conduits on or under plaster as well as for protected installation in luminaires. Not permitted for: direct installation in plaster! Installation on trays, in conduits (except for covered plastic conduits) and the like. Approved for the internal wiring of devices for a mains voltage up to 1000 V AC and up to 750 V DC against earth. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U = 450/750 V Maximum permissible operating voltage: Three-phase and AC current Uo/U = 495/825 V; DC current Uo/U = 743/1238 V; Test AC voltage = 2500 V Installation note: When wiring in luminaires where the connection area of the cores is not protected from UV radiation and heat (caused by the light sources), a protective sleeve must always be pushed over the exposed cores. Otherwise, insulation decomposition will occur depending on the operating time. Technical data Cable type H07V-K Cross-section 4mm² Color Light blue
⚡ 4mm² Hellblau
EBROM H07V-U single-core wire rigid 4mm² light blue 1,31 €
H07V-U rigid installation wire High-quality rigid installation wire, ideal for fixed installation. Technical information Fire reaction class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Cl.1 = single-wire Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Cold-resistant according to EN 60811-504+505+506: Yes Single-wire VDE 0281 Application: for protected installation in equipment as well as in and on luminaires. Approved for installation in conduits on and under plaster, but only for signal systems. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U= 300/500 V, maximum permissible operating voltage, three-phase and alternating current Uo/U= 330/550 V, direct current Uo/U = 495/825 V, test alternating voltage = 2000 V Installation note: When wiring luminaires where the connection area of the wires is not protected from UV radiation and heat (caused by the lamps), a protective sleeve must be placed over the exposed wires. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H07V-U Cross-section 4mm² Color Light blue Nominal voltage 300/500V Standard VDE 0281
⚡ 4mm² Dunkelblau
EBROM H07V-K flexible wire 4mm² dark blue 1,84 €
H07V-K flexible wiring cable High-quality flexible multi-strand wiring cable. Technical information Reaction to fire class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Class 5 = finely stranded Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Finely stranded VDE 0281 Application: In dry rooms, in equipment, switchgear and distribution systems, in conduits on or under plaster as well as for protected installation in luminaires. Not permitted for: direct installation in plaster! Installation on cable trays, in troughs (except for covered plastic troughs) and the like. Approved for the internal wiring of devices for a mains voltage of up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U = 450/750 V Maximum permissible operating voltage: Three-phase and AC current Uo/U = 495/825 V; DC current Uo/U = 743/1238 V; AC test voltage = 2500 V Installation note: When wiring in luminaires where the connection area of the cores is not protected from UV radiation and heat (caused by the illuminants), a protective sleeve must always be pushed over the exposed cores. Otherwise, decomposition of the insulation will occur depending on the duty cycle. Technical data Cable type H07V-K Cross-section 4mm² Color Dark blue
⚡ 4mm² Grün/Gelb
EBROM H07V-K flexible single core wire 4mm² green/yellow 1,84 €
H07V-K flexible wiring cable High-quality flexible multi-strand wiring cable. Technical information Reaction to fire class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Class 5 = fine-stranded Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Fine-stranded VDE 0281 Application: In dry rooms, in equipment, switchgear and distribution cabinets, in conduits on or under plaster as well as for protected installation in luminaires. Not permitted for: direct installation in plaster! Installation on trays, in conduits (except covered plastic conduits) and similar. For internal wiring of devices approved for a mains voltage of up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U = 450/750 V Maximum permissible operating voltage: Three-phase and AC current Uo/U = 495/825 V; DC current Uo/U = 743/1238 V; Test AC voltage = 2500 V Installation note: When wiring luminaires where the connection area of the wires is not protected from UV radiation and heat (caused by the light sources), a protective sleeve must be placed over the exposed wires as a general rule. Otherwise, the insulation will decompose depending on the operating time. Technical data Cable type H07V-K Cross-section 4mm² Colour Green/Yellow
⚡ 4mm² Grün/Gelb
EBROM H07V-U single-core wire rigid 4mm² green/yellow 1,31 €
H07V-U rigid installation wire High-quality rigid installation wire, ideal for fixed installation. Technical information Fire class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Cl.1 = single-wire Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Cold-resistant according to EN 60811-504+505+506: Yes Single-wire VDE 0281 Usage: for protected installation in equipment as well as in and on luminaires. Approved for installation in conduits on and under plaster, but only for signal systems. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U= 300/500 V, maximum permissible operating voltage, three-phase and AC current Uo/U= 330/550 V, DC current Uo/U = 495/825 V, test AC voltage = 2000 V Installation note: When wiring luminaires where the connection area of the wires is not protected from UV radiation and heat (caused by the illuminants), a protective sleeve must always be pushed over the exposed wires. Otherwise, decomposition of the insulation will occur depending on the duty cycle. Technical data Cable type H07V-U Cross-section 4mm² Colour Green/Yellow Nominal voltage 300/500V Standard VDE 0281
⚡ 6mm² Schwarz
Bestseller
EBROM H07V-K flexible single-core wire 6mm² black 2,40 €
H07V-K flexible wiring cable High-quality flexible multi-strand wiring cable. Technical information Reaction to fire class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Class 5 = fine-stranded Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Fine-stranded VDE 0281 Usage: In dry rooms, in equipment, switchgear and distribution cabinets, in conduits on or under plaster as well as for protected installation in luminaires. Not permitted for: direct installation in plaster! Installation on cable trays, in troughs (except covered plastic troughs) and the like. Approved for the internal wiring of devices for a mains voltage up to 1000 V AC and up to 750 V DC against earth. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U = 450/750 V Maximum permissible operating voltage: Three-phase and AC voltage Uo/U = 495/825 V; DC voltage Uo/U = 743/1238 V; Test AC voltage = 2500 V Installation note: When wiring in luminaires where the connection area of the cores is not protected from UV radiation and heat (generated by the light sources), a protective tube must always be slid over the exposed cores. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H07V-K Cross-section 6mm² Colour Black
⚡ 6mm² Schwarz
EBROM H07V-U single-core wire rigid 6mm² black 1,72 €
H07V-U rigid wiring cable High-quality rigid wiring cable, ideal for fixed installation. Technical information Fire behavior class according to EN 13501-6: Eca Flame-retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Cl.1 = single-wire Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Cold-resistant according to EN 60811-504+505+506: Yes Single-wire VDE 0281 Application: for protected installation in devices as well as in and on luminaires. Approved for installation in conduits on and under plaster, however, only for signal systems. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U= 300/500 V, Maximum permissible operating voltage, three-phase and alternating current Uo/U= 330/550 V, direct current Uo/U = 495/825 V, test alternating voltage = 2000 V Installation instruction: When wiring in luminaires where the connection area of the cores is not protected against UV radiation and heat (caused by the illuminants), a protective sleeve must generally be pushed over the exposed cores. Otherwise, decomposition of the insulation occurs depending on the duty cycle. Technical data Cable type H07V-U Cross-section 6mm² Color Black Nominal voltage 300/500V Standard VDE 0281
⚡ 6mm² Schwarz
EBROM HI-FLEX Battery Cable highly flexible 6mm² Black 7,55 €
HIGH-Flexible EBROM battery cable type: HI-FLEX (also known as: Hi-Flex PVC Welding Cable) Easy to process and install due to the extremely flexible properties of the many copper strands and the special sheathing. 99.9% OFC full copper, highest quality grade. Technical data Operating temperature: -30° C to +70° C fixed installation Operating temperature: +5° C to +70° C mobile use Please check the temperature of the place of use/area of application before use!! Minimum installation temperature: 0° C - Maximum temperature in case of short circuit + 160° C at the conductor (max. duration 5 seconds) Protected installation is recommended! Not for use outdoors or in the ground Keep away from hot components and oils! Article class and specifications Article class: Core cable Conductor class: Class 5 = finely stranded Core insulation: PVC (70 ± 5 Shore) Nominal voltage: U0 450 V, U 750 V Standards according to: IEC 20-29 IEC 20-52 EN 60332-1 IEC 50265 Conductor material: Copper, bare, 99.99% OFC With a finely stranded copper wire, the nominal cross-section cannot be reliably determined from the diameter of the wire bundle, not even with a caliper. Use the cable imprint or the data sheet. The circular area calculation using the circle formula A = π × d² / 4 applies to a solid, circular conductor. The sheath and insulation are not part of the conductor area. We are happy to help if you have any questions regarding classification. Technical data Cable type HI-FLEX Cross-section 6mm² Color Black
⚡ 6mm² Schwarz
EBROM NYY-J Underground Cable 6mm² Black 4,08 €
Underground cable/earthing cable NYY-J with copper conductor 1x6mm² Suitable for fixed installation in cable ducts, outdoors, in the ground, in water, but also suitable for indoor use (indoor typically NYM-J ... mm² in GREY) provided that no special mechanical stresses are to be expected Technical data Cable type NYY-J Cross-section 6mm² Colour Black Temperature range -5°C to +50°C
⚡ 6mm² Rot
EBROM H07V-K flexible core wire 6mm² red 2,40 €
Battery cable for many areas of application - 99.9% OFC copper - sold by the meter according to customer requirements - various cross-sections - With a fine-stranded copper wire, the nominal cross-section cannot be reliably determined from the diameter of the wire bundle, not even with a caliper. Please use the cable imprint or the data sheet. The circular area calculation using the circle formula A = π × d² / 4 applies to a solid, circular conductor. The sheath and insulation are not part of the conductor area. We are happy to help if you have any questions regarding identification. Technical data Cable type H07V-K Cross-section 6mm² Color Red
⚡ 6mm² Rot
EBROM HI-FLEX battery cable highly flexible 6mm² red 7,55 €
HIGHLY-flexible EBROM battery cable type: HI-FLEX (also known as: Hi-Flex PVC Welding Cable). Easy to process and route due to the extremely flexible properties of the many copper strands and the special sheathing. 99.9% OFC full copper, highest quality level. Technical data: Operating temperature: -30°C to +70°C fixed installation. Operating temperature: +5°C to +70°C mobile use. Please check the temperature of the application site/area before use!! Minimum installation temperature: 0°C - Maximum temperature during short circuit +160°C at the conductor (max. duration 5 seconds). Protected installation is recommended! Not for use outdoors or in the ground. Keep away from hot components and oils! Article class and specifications: Article class: Core cable. Conductor class: Class 5 = finely stranded. Core insulation: PVC (70 ± 5 Shore). Nominal voltage: U0 450 V, U 750 V. Standards according to: IEC 20-29, IEC 20-52, EN 60332-1, IEC 50265. Conductor material: Copper, bare, 99.99% OFC. With a finely stranded copper wire, the nominal cross-section cannot be reliably determined from the diameter of the wire bundle, not even with a caliper. Please use the cable imprint or the data sheet. The circular area calculation using the circle formula A = π × d² / 4 applies to a solid, circular conductor. The sheath and insulation are not part of the conductor area. We are happy to help if you have any questions regarding classification. Technical data Cable type HI-FLEX Cross-section 6mm² Color Red
⚡ 6mm² Blau
EBROM H07V-K flexible wire 6mm² blue 2,40 €
Battery cable core wire BLUE H07V-K 4-6 - 10-16 - 25 – 35 – 50 – 70-95 mm² - Battery cable 99.9% copper - Sold by the meter 4mm² 6mm² 10mm² 16mm² 25mm² 35mm² 50mm² 70mm² - Caravan, truck, boat Technical data Cable type H07V-K Cross-section 6mm² Color Blue

Free standard shipping to Germany from €60

Fast shipping within Germany

In-house German assembly

Cable assemblies from our own production

Specialist Consulting

Consultation by phone at +49 8074 9176911
PayPal Visa Mastercard SEPA Klarna