⚡ 6mm² Braun
EBROM H07V-K flexible single-core wire 6mm² brown 2,40 €
H07V-K flexible wiring cable High-quality flexible stranded wiring cable. Technical information Reaction to fire class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Class 5 = fine-stranded Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Fine-stranded VDE 0281 Application: In dry rooms, in equipment, switchgear and distribution systems, in conduits on or under plaster as well as for protected installation in luminaires. Not permitted for: direct installation in plaster! Installation on cable trays, in troughs (except for covered plastic troughs) and the like. For the internal wiring of devices approved for a mains voltage up to 1000 V AC and up to 750 V DC against earth. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U = 450/750 V Maximum permissible operating voltage: Three-phase and AC current Uo/U = 495/825 V; DC current Uo/U = 743/1238 V; Test AC voltage = 2500 V Installation note: For wiring in luminaires where the connection area of the cores is not protected from UV radiation and heat (caused by the light sources), a protective sleeve must always be pushed over the exposed cores. Otherwise, decomposition of the insulation will occur depending on the operating time. Technical data Cable type H07V-K Cross-section 6mm² Colour Brown
⚡ 6mm² Grau
EBROM H07V-K Flexible Single Core Cable 6mm² Grey 2,40 €
H07V-K flexible wiring cable High-quality flexible multi-stranded wiring cable. Technical information Reaction to fire class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Class 5 = fine-stranded Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Fine-stranded VDE 0281 Application: In dry rooms, in equipment, switchgear and distribution boards, in conduits on or under plaster, as well as for protected installation in luminaires. Not permitted for: direct installation in plaster! Installation on trays, in troughs (except for covered plastic troughs) and the like. Approved for internal wiring of equipment for a mains voltage of up to 1000 V AC and up to 750 V DC against earth. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U = 450/750 V Maximum permissible operating voltage: Three-phase and AC current Uo/U = 495/825 V; DC current Uo/U = 743/1238 V; Test AC voltage = 2500 V Installation note: When wiring luminaires where the connection area of the wires is not protected from UV radiation and heat (generated by the lamps), a protective sleeve must always be pushed over the exposed wires. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H07V-K Cross-section 6mm² Color Gray
⚡ 6mm² Grau
EBROM NYM-J Installation Cable 6mm² Grey 2,02 €
Earthing cable - not an underground cable! - GREY with 100% OFC copper conductor, rigid single core, in accordance with STANDARD - sheathed cable VDE 0281, part 204. Use: Installation over, on, in and under plaster in dry, damp and wet rooms as well as in masonry and concrete, except for direct embedding in vibrated, shaken or tamped concrete. Also suitable for outdoor use, provided it is protected from direct sunlight, but not for underground use. Technical data Cable type NYM-J Cross-section 6mm² Color Grey
⚡ 6mm² Hellblau
EBROM H07V-K flexible single core wire 6mm² light blue 2,40 €
H07V-K flexible wiring cable High-quality flexible multi-strand wiring cable. Technical information Reaction to fire class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Class 5 = fine-stranded Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Fine-stranded VDE 0281 Application: In dry rooms, in equipment, switchgear and distribution cabinets, in conduits on or under plaster as well as for protected installation in light fittings. Not permitted for: direct installation in plaster! Installation on cable trays, in troughs (except for covered plastic troughs) and the like. Approved for internal wiring of equipment for a mains voltage up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U = 450/750 V Maximum permissible operating voltage: Three-phase and AC current Uo/U = 495/825 V; DC current Uo/U = 743/1238 V; Test AC voltage = 2500 V Installation note: When wiring in light fittings where the connection area of the wires is not protected from UV radiation and heat (generated by the light source), a protective sleeve must always be pushed over the exposed wires. Otherwise, decomposition of the insulation will occur depending on the operating time. Technical data Cable type H07V-K Cross-section 6mm² Color Light blue
⚡ 6mm² Hellblau
EBROM H07V-U single-core wire rigid 6mm² light blue 1,72 €
H07V-U rigid installation wire High-quality rigid installation wire, ideal for fixed installation. Technical information Fire reaction class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Cl.1 = solid Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Cold-resistant according to EN 60811-504+505+506: Yes Solid VDE 0281 Application: for protected installation in equipment as well as in and on luminaires. Approved for installation in conduits on and under plaster, but only for signaling systems. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U= 300/500 V, maximum permissible operating voltage, three-phase and alternating current Uo/U= 330/550 V, direct current Uo/U = 495/825 V, test alternating voltage = 2000 V Installation note: When wiring luminaires where the connection area of the wires is not protected from UV radiation and heat (caused by the light sources), a protective sleeve must always be pushed over the exposed wires. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H07V-U Cross-section 6mm² Color Light blue Nominal voltage 300/500V Standard VDE 0281
⚡ 6mm² Dunkelblau
EBROM H07V-K flexible single core wire 6mm² dark blue 2,40 €
H07V-K flexible wiring cable High-quality flexible multi-stranded wiring cable. Technical information Reaction to fire class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Class 5 = finely stranded Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Finely stranded VDE 0281 Application: In dry rooms, in equipment, switchgear and distribution systems, in conduits on or under plaster, as well as for protected installation in luminaires. Not permitted for: direct installation in plaster! Installation on cable trays, in troughs (except for covered plastic troughs) and the like. Approved for internal wiring of equipment for a mains voltage up to 1000 V AC and up to 750 V DC to earth. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U = 450/750 V Maximum permissible operating voltage: Three-phase and AC current Uo/U = 495/825 V; DC current Uo/U = 743/1238 V; Test AC voltage = 2500 V Installation note: When wiring in luminaires where the connection area of the cores is not protected from UV radiation and heat (caused by the light sources), a protective sleeve must always be pushed over the exposed cores. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H07V-K Cross-section 6mm² Color Dark blue
⚡ 6mm² Grün/Gelb
EBROM H07V-K Flexible Single Core Wire 6mm² Green/Yellow 2,40 €
H07V-K flexible wiring cable High-quality flexible multi-strand wiring cable. Technical information Fire behavior class according to EN 13501-6: Eca Flame-retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Cl.5 = finely stranded Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Finely stranded VDE 0281 Application: In dry rooms, in equipment, switchgear and distribution systems, in conduits on or under plaster as well as for protected installation in luminaires. Not permitted for: direct installation in plaster! Installation on trays, in conduits (except for covered plastic conduits) and the like. Approved for internal wiring of appliances for a mains voltage up to 1000 V AC and up to 750 V DC against earth. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U = 450/750 V Maximum permissible operating voltage: Three-phase and AC current Uo/U = 495/825 V; DC current Uo/U = 743/1238 V; Test AC voltage = 2500 V Installation note: For wiring in luminaires where the connection area of the wires is not protected against UV radiation and heat (caused by the light sources), a protective sleeve must always be pushed over the exposed wires. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H07V-K Cross-section 6mm² Color Green/Yellow
⚡ 6mm² Grün/Gelb
EBROM H07V-U rigid core wire 6mm² green/yellow 1,72 €
H07V-U rigid installation wire High-quality rigid installation wire, ideal for fixed installation. Technical information Fire behavior class according to EN 13501-6: Eca Flame retardant according to VDE 0482-332-1-2/IEC 60332-1-2 Conductor class: Cl.1 = single-wire Core insulation material: PVC Max. permissible conductor temperature: 70 °C Nominal voltage U: 750 V Nominal voltage U0: 450 V Permissible cable outer temperature during installation/handling: 5...70 °C Permissible cable outer temperature after installation without vibration: -25...70 °C Cold-resistant according to EN 60811-504+505+506: Yes Single-wire VDE 0281 Application: for protected installation in equipment as well as in and on luminaires. Approved for installation in conduits on and under plaster, but only for signal systems. Temperature range: maximum conductor temperature 70 °C Technical data: Nominal voltage Uo/U= 300/500 V, maximum permissible operating voltage, three-phase and AC current Uo/U= 330/550 V, DC current Uo/U = 495/825 V, test AC voltage = 2000 V Installation instruction: When wiring in luminaires where the connection area of the cores is not protected from UV radiation and heat (caused by the illuminants), a protective sleeve must always be pushed over the exposed cores. Otherwise, depending on the duty cycle, decomposition of the insulation will occur. Technical data Cable type H07V-U Cross-section 6mm² Color Green/Yellow Nominal voltage 300/500V Standard VDE 0281
⚡ 10mm² Schwarz
EBROM H07V-K flexible single-core wire 10mm² black 2,94 €
Flexible EBROM battery cable type H07V-K. Easy to process and install due to the flexible properties of the many copper strands. 99.9% OFC full copper, highest quality level. Technical data: Max. operating temperature (fixed installation): -30°C to +80°C. Max. operating temperature (moved): -5°C to +70°C. Please check the temperature of the place of use/area of application before use!! Protected installation is recommended! Keep away from hot components and oils! Article class and specifications: Article class: Core cable. Conductor class: Class 5 = fine-stranded. Core insulation: PVC. Nominal voltage: U0 450 V, U 750 V. Conductor material: Copper, bare, 99.99% OFC. With a fine-stranded copper strand, the nominal cross-section cannot be reliably determined from the diameter of the wire bundle, not even with a caliper gauge. Please use the cable imprint or the data sheet. The circular area calculation using the circle formula A = π × d² / 4 applies to a solid, circular conductor. Sheathing and insulation are not part of the conductor area. We are happy to help with questions regarding classification. Technical data Cable type H07V-K Cross-section 10mm² Color Black
⚡ 10mm² Schwarz
EBROM HI-FLEX Battery Cable highly flexible 10mm² Black 9,40 €
HIGHLY flexible EBROM battery cable Type: HI-FLEX (also known as: Hi-Flex PVC Welding Cable) Easy to process and install due to the extremely flexible properties of the many copper strands and the special sheathing. 99.9% OFC full copper, highest quality level. Technical data Operating temperature: -30°C to +70°C fixed installation Operating temperature: +5°C to +70°C mobile use Please check the temperature of the place of use/area of application before use!! Minimum installation temperature: 0°C - Maximum temperature during short circuit + 160°C at the conductor (max. duration 5 seconds) Protected installation is recommended! Not for use outdoors or in the ground Keep away from hot components and oils! Article class and specifications Article class: Core cable Conductor class: Class 5 = finely stranded Core insulation: PVC (70 ± 5 Shore) Nominal voltage: U0 450 V, U 750 V Standards according to: IEC 20-29 IEC 20-52 EN 60332-1 IEC 50265 Conductor material: Copper, bare, 99.99% OFC With a finely stranded copper wire, the nominal cross-section cannot be reliably determined from the diameter of the wire bundle, not even with a caliper. Use the cable print or the data sheet. The circular area calculation using the circle formula A = π × d² / 4 applies to a solid, circular conductor. The sheath and insulation are not part of the conductor area. We are happy to help if you have any questions regarding classification. Technical data Cable type HI-FLEX Cross-section 10mm² Color Black
⚡ 10mm² Rot
EBROM H07V-K flexible single-core wire 10mm² Red 2,94 €
Battery cables for many areas of application - 99.9% OFC copper - sold by the meter according to customer requirements - various cross-sections - For fine-stranded copper wire, the nominal cross-section cannot be reliably determined from the diameter of the wire bundle, not even with a caliper. Use the cable imprint or the data sheet. The circular area calculation using the circle formula A = π × d² / 4 applies to a solid, circular conductor. The sheath and insulation are not part of the conductor area. If you have any questions about classification, we are happy to help. Technical data Cable type H07V-K Cross-section 10mm² Color Red
⚡ 10mm² Rot
EBROM HI-FLEX battery cable highly flexible 10mm² red 9,40 €
HIGHLY-flexible EBROM battery cable type: HI-FLEX (also known as: Hi-Flex PVC Welding Cable) Easy to process and install due to the extremely flexible properties of the many copper strands and the special sheathing. 99.9% OFC full copper, highest quality level. Technical data Operating temperature: -30°C to +70°C fixed installation Operating temperature: +5°C to +70°C mobile use Please check the temperature of the place of use/area of application before use!! Minimum installation temperature: 0°C - Maximum short-circuit temperature + 160°C at the conductor (max. duration 5 seconds) Protected installation is recommended! Not for outdoor or underground use Keep away from hot components and oils! Article class and specifications Article class: Core cable Conductor class: Class 5 = fine-stranded Core insulation: PVC (70 ± 5 Shore) Nominal voltage: U0 450 V, U 750 V Standards according to: IEC 20-29 IEC 20-52 EN 60332-1 IEC 50265 Conductor material: Copper, bare, 99.99% OFC For a fine-stranded copper cable, the nominal cross-section cannot be reliably determined from the diameter of the wire bundle, not even with a caliper. Please use the cable imprint or the data sheet. The circular area calculation using the circle formula A = π × d² / 4 applies to a solid, circular conductor. The sheath and insulation are not part of the conductor area. We are happy to help if you have any questions regarding classification. Technical data Cable type HI-FLEX Cross-section 10mm² Colour Red
⚡ 10mm² Blau
EBROM H07V-K Flexible Single Core Wire 10mm² Blue 2,94 €
Flexible EBROM battery cable of type H07V-K. Easy to process and install due to the flexible properties of the many copper strands. 99.9% OFC full copper, highest quality level. Technical data: Max. operating temperature (fixed installation): -30°C to +80°C. Max. operating temperature (moved): -5°C to +70°C. Please check the temperature of the place of use/area of application before use!! Protected installation is recommended! Keep away from hot components and oils! Article class and specifications: Article class: Core cable. Conductor class: Class 5 = fine-stranded. Core insulation: PVC. Nominal voltage: U0 450 V, U 750 V. Conductor material: Copper, bare, 99.99% OFC. With a fine-stranded copper wire, the nominal cross-section cannot be reliably determined from the diameter of the wire bundle, not even with a caliper. Use the cable imprint or the data sheet. The circular area calculation using the circle formula A = π × d² / 4 applies to a solid, circular conductor. The sheath and insulation are not part of the conductor area. We are happy to help if you have any questions regarding allocation. Technical data Cable type H07V-K Cross-section 10mm² Color Blue
⚡ 10mm² Grau
EBROM NYM-J Installation Cable 10mm² Gray 3,24 €
Earthing cable - not an underground cable! - GREY with 100% OFC copper conductor, rigid single core, in accordance with STANDARD - sheathed cable VDE 0281, part 204. Use: Installation above, on, in and under plaster in dry, damp and wet rooms as well as in masonry and concrete, except for direct embedding in vibrated, shaken or tamped concrete. Also suitable for outdoor use, provided it is protected from direct sunlight, but not for underground use. Technical data Cable type NYM-J Cross-section 10mm² Colour Grey
⚡ 10mm² Grün/Gelb
EBROM H07V-K Flexible Single Core Wire 10mm² Green/Yellow 2,94 €
Installation instruction: For wiring in luminaires where the connection area of the wires is not protected from UV radiation and heat (generated by the light sources), a protective sleeve must always be pushed over the exposed wires. Otherwise, depending on the operating time, decomposition of the insulation will occur. Not permitted for direct installation under plaster. Further areas of application: wiring of control cabinets, connection of meters, distribution board construction, mechanical engineering, wiring of fuses Technical data Cable type H07V-K Cross-section 10mm² Color Green/Yellow

Free standard shipping to Germany from €60

Fast shipping within Germany

In-house German assembly

Cable assemblies from our own production

Specialist Consulting

Consultation by phone at +49 8074 9176911
PayPal Visa Mastercard SEPA Klarna